Back to Top

1
Hi, Guest!
  • 3nh 3nh
  • 3nh YS6060 Benchtop Grating Spectrophotometerindonesia

3nh YS6060 Benchtop Grating Spectrophotometerindonesia

Update Terakhir
:
16 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail 3nh YS6060 Benchtop Grating Spectrophotometerindonesia

Alat Laboratorium Mikrobiologi

Model
YS6060 Benchtop Spectrophotometer
Optical Geometry
Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3Model
YS6060 Benchtop Spectrophotometer
Optical Geometry
Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;
SCI (specular component included)/SCE (specular component excluded) ;
978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Application
It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere Size
Φ154mm
Light Source
360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source
Spectrophotometric Mode
Concave Grating
Sensor
256 Image Element Double Array CMOS Image Sensor
Wavelength Range
360-780nm
Wavelength Interval
10nm
Semiband Width
10nm
Measured Reflectance Range
0-200%
Measuring Aperture
Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Component
Reflectance: SCI&SCE / Transmittance: SCI&SCE
Color Space
CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula
ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric Index
WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
TI (ASTM E313, CIE/ISO),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle
2°/10°
Illuminant
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed Data
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time
About 2.4s (Measure SCI & SCE about 5s)



Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208








Alat laboratorium umum
Tampilkan Lebih Banyak
Kontak Kami