This current probe measures up to 1200AAC. Specifications include:

Accuracy: ±0.3%
Conductor size: 2.05" (52mm)
Cable length: 10' (3m)
Dimensions: 8.5 x 4.4 x 1.8" (21.c x 11.1 x 4.5cm)
Weight: 24 oz (690g)
This probe is designed for use with Power Quality Analyzers Models 3945/3945B, 8220, 8230, 8333, 8335, and 8336; Power & Energy Loggers Models PEL 102, 103, and 105; and Simple Logger II Models L104 and L564.

Specifications:

Clamping Diameter
2” (52mm)
Current Range
1200AAC
Measurement Range
1 to 1200AAC
Lead Length
10 ft (3m)
Output Termination
Proprietary connector
Accuracy (Typical)
±0.3%
Power Source
N/A
Compatibility
AEMC PowerPads and PELs
Operating Temperature
14° to +131°F (-10° to +55°C); 10 to 85% RH
Storage Temperature
-40° to +158°F (-40° to +70°C); 10 to 90% RH
Dimensions
8.5 x 4.4 x 1.8” (216 x 111 x 45mm)
Weight
24 oz (690g)
Pollution Degree
2
Protection
IK 04, IP40 (jaws closed), IP30 (jaws open)
Safety Compliance
IEC 61010-1, IEC 61010-2-032, 1000V CAT III, 600V CAT IV
AC Current Probe Model MN114
The MN114 is a general purpose mini probe which offers 1mA to 10AAC, continuous cycle current range. The output signal is 100mVAC/AAC (1V at 10A). It was designed to optimize measurements on 5A signals. The output termination is a 5ft lead with safety 4mm banana plug.

Specifications:
Maximum Clamping Diameter
0.47" (12mm)
Current Range
10Arms AC
Measurement Range
1mA to 10AAC
Output Signal
100mVAC / AAC (1V @ 10A)
Transformation Ratio
N/A
Output
5 ft (1.5m) lead with 4mm safety banana plug
Accuracy 50/60Hz
2% R ± 2mA (typical)
Frequency Range
30Hz to 5kHz
Phase Shift at 50/60Hz
<8°
Open Secondary Voltage
N/A
Load Impedance
100kΩ min
Dimensions (HxWxD)
1.26 x 4.5 x 0.87” (32 x 115 x 22mm)
Weight
6 oz (160g)
Operating Temperature
-13° to +122°F (-25° to +55°C)
Storage Temperature
-40° to +176°F (-40° to +80°C)
Rating
UL 94 V0
Safety
250V working voltage, 30V max common mode between output and ground, 3kV 50/60Hz dielectric for 1mm. This probe is not CE marked.