Back to Top

1
Hi, Guest!
  • AEMC AEMC
  • AEMC Clamp-on Leakage Current Meter Model 566

AEMC Clamp-on Leakage Current Meter Model 566

Update Terakhir
:
21 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail AEMC Clamp-on Leakage Current Meter Model 566

Alat Laboratorium Mikrobiologi

Deskripsi produk
Clamp-on Leakage Current Meter Model 566
The TRMS Clamp-On Leakage Current Meter Model 566 is designed to measure low AC currents, which are typically leakage currents in ground conductors. Low currents are measured in the 60mA and 600mA ranges. The high sensitivity of the probe (1µA, 10µA and 100µA) resolution when measuring mA is possible through special jaw construction and, in particular, critical shielding of the jaws. At low measurement levels, shielding out noise is critical for low sensitivity, accuracy, and stability.

The Model 566 can be used as a standard clamp-on meter measuring to 60Arms, as well as VAC and VDC ranges, resistance and continuity with a buzzer. In mAAC and AAC, the user can activate a low-pass filter (LPF) to ignore all currents other than 50/60Hz. In this mode, only the fundamental signal is measured.

The Model 566 is ergonomic in design and fits well in the hand, facilitating one hand operation. The jaw size is compact yet designed to accommodate the most common conductors up to 0.91" (23mm) in diameter.

Specification:

Voltage Range:
600Vrms AC/DC Auto-Ranging
Resolution Max:
0.01V
Current Range (mA):
6 / 60 / 600mArms AC
Current Range (A):
6.0 / 60Arms AC
Resolution Max:
1 µA
Accuracy V Typical:
1.0% ± 3cts
Accuracy A Typical:
1.0% ± 3cts
Continuity:
<45Ω
Resistance:
600kΩ
Frequency Range:
500Hz in V, A
Power Source:
2 x AAA, IEC LR03
Battery Life:
40 hours at ACmA, ACA and ACV functions
60 hours at DCV and Ohm functions
Dimensions:
8.27 x 3 x 1.32" (210 x 76 x 33.5mm)
Weight:
10.4 oz. (296g) with batteries
Jaw Opening:
.91" (23mm)
Operating Temperature:
+32° to 104°F (0° to +40°C)
Storage Temperature:
+14° to 140°F (-10° to +60°C)
Operating Humidity:
80% up to 104°F (40°C)
Safety Compliance:
EN/IEC 61010 600V CAT III