Detail AEMC Ground Resistance Tester Model 6417
Alat Laboratorium Mikrobiologi
Deskripsi produk
Ground Resistance Tester Model 6417
The Ground Resistance Tester Model 6417 measures ground rod and grid resistance and impedance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting or de-energizing the ground system under test. The Model 6417 simply clamps around the grounding electrode or conductor and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.
Specifications:
Ground Resistance Measurement (Auto-Ranging 1 to 199Ω)
Measurement Range
Resolution
Accuracy
0.010 to 0.099Ω
0.001Ω
±(1.5%Reading +0.01Ω)
0.10 to 0.99Ω
0.01Ω
±(1.5%Reading +0.02Ω)
1 to 49.9Ω
0.1Ω
±(1.5% Reading +0.1Ω)
50.0 to 99.5Ω
0.5Ω
±(2% Reading +0.5Ω)
100 to 199Ω
1Ω
±(3% Reading +1Ω)
200 to 395Ω
5Ω
±(5% Reading +5Ω)
400 to 590Ω
10Ω
±(10% Reading +10Ω)
600 to 1150Ω
50Ω
20% approx.
1200 to 1500Ω
50Ω
25% approx.
Alarm
Adjustable from 1 to 199Ω
Frequency Selection
Choice of 50, 60, 128, or 2083Hz for impedance calculation
Maximum Overload
Permanent current: 100 max. 50/60Hz
Transient current: (<5s) 200A 50/60Hz
Current Measurement Range (Auto-Ranging)
Measurement Range
Resolution
Accuracy
0.200 to 0.999mA
1µA
±(2% Reading +50µA)
1.000 to 2.990mA
10µA
±(2% Reading +50µA)
3.00 to 9.99mA
10µA
±(2% Reading +50µA)
10.00 to 29.99mA
100µA
±(2% Reading +100µA)
30.0 to 99.9mA
100µA
±(2% Reading +100µA)
100 to 299.9mA
1mA
±(2% Reading +1mA)
0.300 to 0.990A
1mA
±(2% Reading +1mA)
1.000 to 2.999A
10mA
±(2% Reading +10mA)
3.00 to 39.99A
10mA
±(2% Reading +10mA)
Loop Inductance Measurement
Measurement range
Resolution
Accuracy
10 to 100µH
1µH
±(5% Reading +1µH)
100 to 500µH
1µH
±(3% Reading +1µH)
Contact Voltage (Touch Voltage) Calculated
Measurement range
Resolution
Accuracy
0.1 to 4.9V
0.1V
±(5% Reading +0.1V)
5.0 to 49.5V
0.5V
±(5% Reading +0.5V)
50 to 75.0V
1V
±(10% Reading +1V)
General Features
Display
OLED, 152 segments 48x39mm
Memory
2000 measurements
Communication
Bluetooth, DataView software included
Alarm
3 separate alarms (Ω, V and A)
Power Source
4x1.5V LR6 (AA) alkaline batteries or 4 NiMH batteries
Battery Life
12 hours or 1440 30-seconds tests approx.
Jaw Opening
1.38” (35mm) max
Dimensions
2.16 x 3.74 x 10.31” (55 x 95 x 262mm)
Weight (with Battery)
2.06 lbs (935g)
Operating Temperature
-4° to +131°F (-20 to +55°C)
Storage Temperature
-22° to +158°F (-30 to +70°C)
Relative Humidity
Up to 90% @ 40°C
Ingress Protection (IP)
IP 40
EMC
EN 61326-1
Safety Compliance
IEC 61010-1, EN 61010-2-30, EN 61010-2-32, Pollution Degree 2, 600V CAT IV
VT/PT Ratio Range
Auto-Ranging: 0.8000:1 to 8000.0:1
VT/PT Accuracy
0.8000 to 9.9999: ±0.2% of Reading
10.000 to 999.99: ±0.1% of Reading
1000.0 to 4999.9: ±0.2% of Reading
5000.0 to 8000.0: ±0.25% of Reading
CT Ratio Range
Auto-Ranging: 0.8000 to 1000.0
CT Accuracy
±0.5% of Reading
Excitation Signal
VT/PT Mode: 32Vrms max
CT Mode: Auto Level 0 to 1A, 0.1 to 4.5Vrms
Excitation Current Display
Range: 0 to 1000mA
Accuracy: ±(2% of Reading +2mA)
Excitation Frequency
70Hz
Display
LCD 16 character, 2 line, large format, LED backlight, day/night visible
Languages Supported
English, Spanish, French, Italian, German, Portuguese
Communication
Optically isolated USB 2.0
Data Storage
Up to 10,000 complete measurements
Power Source
Two rechargeable 12V NiMH batteries (included)
Battery Life
Up to 10 hours of continuous operation
Low Battery Indication
LED and LCD
External Charger
90 to 240V, 50/60Hz (smart charger)
Charging Time
<4 hours
Measurement Method
In accordance with ANSI/IEEE Std. C57.12.90-2006
Software
DataView analysis software included
Dimensions
10.70 x 9.76 x 5.12” (272 x 248 x 130mm)
Weight
8.1 lbs (3.7kg)
Operation Temperature
14° to 122°F (-10° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 60°C)
Index of Protection
IP40 (lid open), IP53 (lid closed)
Double Insulated
Yes
CE Approved
Yes
Safety Compliance
IEC 61010-1 (1995-A2) 50V CAT IV Pollution 2
VT/PT Ratio Range
Auto-Ranging: 0.8000:1 to 8000.0:1
VT/PT Accuracy
0.8000 to 9.9999: ±0.2% of Reading
10.000 to 999.99: ±0.1% of Reading
1000.0 to 4999.9: ±0.2% of Reading
5000.0 to 8000.0: ±0.25% of Reading
CT Ratio Range
Auto-Ranging: 0.8000 to 1000.0
CT Accuracy
±0.5% of Reading
Excitation Signal
VT/PT Mode: 32Vrms max
CT Mode: Auto Level 0 to 1A, 0.1 to 4.5Vrms
Excitation Current Display
Range: 0 to 1000mA
Accuracy: ±(2% of Reading +2mA)
Excitation Frequency
70Hz
Display
LCD 16 character, 2 line, large format, LED backlight, day/night visible
Languages Supported
English, Spanish, French, Italian, German, Portuguese
Communication
Optically isolated USB 2.0
Data Storage
Up to 10,000 complete measurements
Power Source
Two rechargeable 12V NiMH batteries (included)
Battery Life
Up to 10 hours of continuous operation