Detail AEMC Multi-Function Installation Tester Model C.A 6116N

Alat Laboratorium Mikrobiologi

Deskripsi produk
Multi-Function Installation Tester Model C.A 6116N
The C.A 6116N is a multi-function instrument for testing electrical installations for compliance with national and international standards (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, and others). It features advanced design, ergonomics, simplicity, performance, speed, and accuracy. Suitable for all neutral systems (TT, TN, IT), the instrument is ideal for all sectors including industrial, residential, and others. It measures continuity, resistance, insulation, earth and selective earth, loop impedances, type A and AC RCDs, as well as voltage, frequency, current (via a clamp), active power, harmonics, and phase rotation. The instrument can store up to 1,000 tests, which can be downloaded and processed with the included DataView® data analysis software.

Specifications:
INSULATION
Rated Voltage
Utest: 50 /100 / 250 / 500 / 1000VDC
Range / Resolution / Accuracy
0.01MΩ to 2GΩ / 10kΩ to 1MΩ / ±(5% of Reading +3cts)
Short Circuit Current
≤3mA
CONTINUITY
I rated / Range / Resolution / Accuracy
I > 200mA / 39.99Ω/ 0.01Ω / ±(1.5% of Reading +2cts)
12mA / 39.99Ω & 399.9Ω / 0.01 & 0.1Ω / ±(1.5% of Reading +5cts) with beep
RESISTANCE

Range / Resolution / Accuracy
4kΩ / 1Ω / ±(1.5% of Reading +5cts) 40kΩ - 400kΩ / 10Ω - 100Ω / ±(1.5% of Reading +2cts)
GROUND
3P GROUND
Range / Resolution / Accuracy
0.50Ω to 40Ω/ 0.01Ω / ±(2% of Reading +10cts) 40Ω to 15kΩ / 0.1Ω to 1Ω / ±(2% of Reading +2cts)
15kΩ to 40kΩ / 10Ω/ ±(10% of Reading +2cts)
Others
Measurement of resistance of auxiliary stakes RH & RS (up to 40kΩ)
Ufk
Complies with SEV 3569
1P SELECTIVE GROUND
Range / Resolution / Accuracy
0.20Ω to 39.99Ω - 40Ω to 399.9Ω / 0.01Ω – 0.1Ω / ±(10% of Reading +10cts) (ISel via clamp)
LOOP IMPEDANCE (Zs (L-PE0 AND Zi (L-N OR L-L) – 1P LIVE GROUND
Live Ground
Installation Voltage / Freq.
90 to 500V / 15.8 to 17.5Hz - 45 to 65Hz
High-Current Mode with TRIP
Zs (L- PE) & Zi (L- N or L - L)
Range / Resolution / Accuracy
Max. test current: 7.5A
0.100Ω to 0.5Ω / 0.001Ω/ ±(10% of Reading +20cts) • 0.5Ω to 3.999Ω / 0.001Ω/ ±(5% of Reading +20cts)
3.999 to 39.99Ω/ 0.01Ω / ±(5% of Reading +2cts) • 39.99Ω to 399.99Ω / 0.1Ω/ ±(5% of Reading +2cts)
NO TRIP Mode (Zs (L – PE) only)
Test current 6mA – 9mA – 12mA (as required)
0.20 to 0.99Ω / 0.01Ω / ±(15% of Reading +10cts) 1.00 to 1.99Ω / 0.01Ω / ±(15% of Reading +3cts)
2.00 to 39.99 / 0.01Ω / ±(10% of Reading +3cts) 40.00 to 399.9Ω / 0.1Ω ±(5% of Reading +2cts)
400 to 3999Ω / 1Ω ±(5% of Reading +2cts)
Calculation Of IK Short Circuit Current (PFC (Zs), I Sc PSCC (Zi)
Fault current and short-circuit current: 0.1 to 20kA
Others
Measurement of the resistive and inductive components of Zs and Zi impedances
Type AC and Type A RCDs
Installation Voltage / Frequency
90 to 500V / 15.8 to 17.5Hz and 45 to 65Hz
IΔn
10/30/100/300/500/650/1000mA (90 to 280V)
10/30/100/300/500mA (280 to 550V) or Variable Ramp and Pulse test
N-trip Test
At ½ IΔn – Duration 1,000ms or 2,000ms
Ramp Mode
0.2 to 0.5 x IΔn(Uf) / 0.3 x IΔn to 1.06 IΔn increments of 3.3% x IΔn
Trip Test: Reading:
Range / Resolution / Accuracy
0.2 to 0.5 x IΔn(Uf) / 0.5 x IΔn / 2 x IΔn(selective) / 5 x IΔn
Pulse: 0 to 500ms / 0.1 and 1ms / 2ms, Ramp mode: 0 to 200ms / 0.1ms / 2ms
OTHER MEASUREMENTS
Current By Current Probe C177A
5.0mA to 199.9A (0.5mA with voltage between L and PE)
Current By Current Probe MN77
5.0mA to 19.99A (1mA with voltage between L and PE)
Voltage
0 to 550Vac/dc / DC and 158 to 500Hz
Frequency
10 to 500Hz
Phase Rotation
20 to 500VAC
Active Power
0 to 110kW single-phase / 0 to 330kW three-phase
Simultaneous display of voltage and current waveforms
Harmonics
Voltage and Current / up to 50th order / THD-F / THD-R
GENERAL SPECIFICATIONS
Display
Large 5.7” backlit graphic color LCD (320x240 pixels)
Storage/Communication
USB for data transfer with DataView software (Included)
Battery
Lithium-Ion 10.8V, 5.8Ah
Battery life
Up to 30 hours
Protection
IP 53 / IK04
Dimension
11x7.48x5.04” (280x190x128mm)
Weight
4.85lbs (2.2kg)
EMC
IEC61326-1
Electrical Safety
IEC61010-1 – 600V CAT III – 300V CAT IV – IEC 61557