Detail Anemometer PCE-EM 890
Anemometer PCE-EM 890
Instrument Laboratorium
Deskripsi produk
DESCRIPTION
Anemometer PCE-EM 890
Climate weather measuring device for recording various environmental data / Various measuring functions / MAX / MIN measurement / High accuracy
The anemometer PCE-EM 890 is an instrument for measuring environmental conditions. The anemometer gives you an accurate measurement very quickly. Due to the small dimensions and the low weight, this anemometer is an easy-to-use information system on the weather condition. It is possible to switch between the measuring functions with just one push of a button. Thus, this anemometer is ideal for technicians, sailors, farmers and many other people who are dependent on the weather or whose activities are significantly influenced by the weather.
With just one gauge, you can read wind speed, temperature, wind chill (sensed temperature), dew point, relative humidity, heat index, barometric pressure, and height above sea level. The anemometer offers you the functions of the individual measured value, minimum value, maximum value measurement.
Explanation of various environmental conditions:
Wind Chill
The wind chill describes the difference between the measured air temperature and the sensed temperature as a function of the wind speed. Some of our anemometers can record the wind chill and other parameters.
Air Pressure
The air pressure at any location in the Earth's atmosphere is the hydrostatic pressure of the air that prevails in that location. This pressure is consistent with the weight of the column of air that is on the surface of the earth or a body on it. The average atmospheric pressure of the atmosphere at sea level is 101325 Pa = 1013.25 hPa = 101.325 kPa and is thus part of the normal conditions.
Dew Point / Dew Point Temperature
Air can absorb more water vapor with increasing temperature. With decreasing temperature of a building material or the air, in which the relative humidity of 100% is reached, then the excess water vapor precipitates in the form of condensation. The boundary area is called dew point. Buildings should be designed so that the dew point temperature on the inside of the air tightness layer is not undershot. The formation of condensation and resulting structural damage or mold is thereby avoided. Particularly harmful are air currents through the air tightness layer. In this case, a fall below the dew point is always to be expected. The wet bulb temperature, which plays an important role in the air conditioning industry, for example, is a very important parameter in many other areas.
HIGHLIGHTS
- compact and robust construction
- high precision
- very precise, smooth-running impeller
- easy to read digital display
- backlight
- interchangeable impeller
- Max-Min measurement
- 11 measurement functions in one device
SPECIFICATION
Measuring function Measuring range Resolution Accuracy
Wind speed 80 ... 3937 ft/min 1 ft/min ± 3% of measured value
0.4 ... 20 m/s 0.1 m/s
1.4 ... 72 km/h 0.1 km/h
0.9 ... 44.7 mph 0.1 mph
0.8 ... 38.8 Knots 0.1 Knots
Air temperature Measuring range Resolution Accuracy
0 ... 50°C / 32 ... 122°F 0.1°C / 0.18°F ± 1.2°C / 2.16°F
Humidity Measuring range Resolution Accuracy
10 ... 95% r.H. 0.1% r.H. <70% r.H.: ± 4% r.H.
>70% r.H.: ± 4 of measured value +1.2% r.H.
Barometric- Measuring range Resolution Accuracy
air pressure 10 ... 999.9 hPa 0.1 hPa ± 1.5 hPa
1000 ... 1100 hPa 1 hPa ± 2 hPa
UV A 290 ... 390 nm Measuring range Resolution Accuracy
0 .... 1999 µW/m² 0.1 µW/m² ±(4% of measured value + 2 digits)
2 ... 20 mW/m² 0.01 mW/m²
External temperature Measuring range Resolution Accuracy
(Pt1000 input) -10 ... 70 °C / 14 ...158°F 0.1°C / 0.18 ± 1.2°C / 2.16°F
Volume flow Measuring range Resolution
0.024 ... 3600 cmm 0.001 cmm
0.01 cmm
0.1 cmm
1 cmm
Measuring range Resolution
Dew point -25.3 ... 49°C / 13.54 ... 120.2°F 0.1°C / 0.18°F
Wet bulb temperature Measuring range Resolution
-5.4 ... 49°C / 22.28 ... 120.2°F 0.1°C / 0.18°F
Heat stress index Measuring range Resolution Accuracy
0 ... 100°C / 32 ... 212°F 0.1°C / 0.18°F ± 2°C / 3.6°F
Windchill Measuring range Resolution Accuracy
-9.4 ... 44.2°C / 15.8 ... 111.56°F 0.1°C / 0.18°F ± 2°C / 3.6°F
Height above sea level Measuring range Resolution Accuracy
-2000 ... 9000 m / -6561 ... 29527 ft 1 m / 3 ft 3" ± 15 m
General technical data for the anemometer
Display LC display
8 mm character height
Measurement functions Wind speed / temperature
Display parameters Humidity / temperature
UV
Air pressure
Volume flow
Dew point
Wet bulb temperature
Windchill
Heat stress index
Height above sea level
External temperature over Pt1000
Power supply CR2032 3V batteries
Current consumption ca. 5-mA
Operating conditions 0 ... 50°C / 32 ... 122°F / max. 80% r.H.
Dimensions 120 x 45 x 20 mm / 4.7 x 1.7 x 0.7"
Weight ca. 160 g / < 1 lb
DELIVERY SCOPE
1 x Anemometer PCE-EM 890
1 x CR2032 batteries
1 x User manual
Tampilkan Lebih Banyak