TS8500 Benchtop Grating Spectrophotometer Specification

Model : TS8500 (LED+Pulsed Xenon)
Optical Geometry : Reflect: D/8(diffused illumination, 8-degree viewing angle) ;

SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ;

Transmittance: D/0 (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ;

HAZE (ASTM D1003); Standards meet: CIE No.15, GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7,JIS Z8722 under condition C
Characteristic
1. It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.

2. 10.5 inch rotatable display pad, 128G storage, camera locating

3. Instrument can be measured on the side, upward measurement, and the downward measurement (use accessories) and other gestures.

4. Open transmission warehouse, available thickness of 54mm transmitted samples.

5. Automatic temperature and humidity compensation function.

6. Built-in full spectral high life LED light source and Xenon lighting sources, testing fluorescent samples have better recognition.
Integrating Sphere Size : Φ154mm
Light Source Device : 360nm–780nm Wavelength range ,combined LED Light. Including UV, 400nm cut-off light source, 420nmCut-off light source,360~780nm Xenon Lamp.
Spectrophotometric Mode : Concave Grating
Sensor : 256 Image Element Double Array CMOS Image Sensor
Wavelength Range : 360~780nm
Wavelength Interval : 10nm
Semiband Width : 5nm
Measured Reflectance Range : 0~200%
Reflectivity Resolution : 0.01
Measuring Aperture
Reflective: XLAV Φ25.4mm/Φ30mm, LAVΦ15mm/Φ18mm , MAVΦ8mm/Φ10mm, SAVΦ4mm/Φ6mm

Transmissive: Φ25.4mm(No limit on sample height and width, but thickness≤54mm)

Remark:

1. Automatic identification of aperture switch

2. Customized Configuration caliber and lens position
Specular Component
Reflectance: SCI&SCE / Transmittance: SCI&SCE
Color Space
CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) ,ΔE*CH,555 Index
Other Colorimetric Index
WI(ASTM E313,CIE/ISO,AATCC,Hunter,Taube,Berger Stensby)

YI(ASTM D1925,ASTM 313),ISO brightness,R457

MI (Metamerism Index),

Staining Fastness, Color Fastness, Color Strength, Opacity,

APHA/Hazen/Pt-Co Index,Gardner Index

8° Gloss,555 Index, Haze,Transmission(ASTM D1003), Saybolt index, ASTM D1500 Color code,carbon(My,dM), Color density CMYK(A,T,E,M), Tint,Color density(part function achieved via software in PC)
Observer Angle : 2°/10°
Illuminant
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF

ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, customized light source(41 light sources in total,part achieved via software in PC)
Displayed Data
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color assessment, haze, liquid chromaticity
Measuring Time
2.0s(Measure SCI & SCE meantime about 4s )
Repeatability
Reflectance chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration);

spectrum reflectance /transmission:≤0.1%
Inter-instrument Error : Φ25.4mm/SCI, Within ΔE*ab 0.2
(Average for 12 BCRA Series II color tiles)
Dimension : L*W*H=440x248x283mm
Weight : Approx. 13.5kg
Power : AC 24V, 3A Power adapter power supply
Illuminant Life Span : 5 years, more than 3 million times measurements
Display : 10.5-inch rotatable display pad
Data Port : USB & Bluetooth
Data Storage : 64G storage,above 100000pcs
Language : Simplified Chinese, Traditional Chinese, English,(Optional Customized German,Russian, French ,Spanish ,Japanese, Thai, Korean, Polish, Portuguese)
Operating Environment : 0~40℃(32~104°F)
Storage Environment : -20~50℃(-4~122°F)
Standard Accessory : Power Adapter, User Guide, U Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, cuvette, 10.5-inch screen
Optional Accessory : Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish,Film fixture
Notes : Test reports can be printed through a network printer connected to a PC or display pad; The specifications are subject to change without notice.