Back to Top

1
Hi, Guest!

Cable Detector PCE-LT 12

Update Terakhir
:
18 / 09 / 2024
Min. Pembelian
:
1 Unit

Harga

Rp. 100
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail Cable Detector PCE-LT 12


Cable Detector PCE-LT 12
Instrument Laboratorium

Deskripsi produk
DESCRIPTION
Cable detector PCE-LT 12
Voltage tester with many measuring functions / For electricians and IT employees / Analysis of network connection cables / Telephone connection test / Voltage and current measurement / NCV / backlight
The voltage tester is a versatile measuring instrument. In addition to the standard voltage and current measurements, the voltage tester also has a network analysis. With this network analysis, the voltage tester can be used to check, for example, LAN connections for their correct wiring and function. Telephone connections can also be checked for their function with this voltage tester. If cables can not be found again, the voltage tester also helps here.


Thanks to the cable finder function of the voltage tester, the operator can find the required cable in no time at all. To do this, the voltage tester must be connected to the connection of a cable. The voltage tester now acts as a transmitter. With the supplied receiver you can now easily find the desired cable in, for example, a wiring harness or behind walls with the voltage tester.

To check whether a voltage is applied to a cable, the voltage tester has an NCV (Not Connected Voltage) function. With this function, the voltage tester must only be held to the line. Both acoustically and visually, the voltage tester signals the operator that a voltage is applied to the line. Thanks to this contactless measuring function, the voltage tester reduces accidents at work due to electric shock.
HIGHLIGHTS
- Extensive network connection testing
- Telephone connection examination
- Acoustic cable finder function
- Robust housing for mobile use
- Voltage, current, resistance measurement
- Contactless voltage detection
SPECIFICATION
Measuring function

AC

Measuring range
Resolution
Accuracy
200 mV
0.1 mV
± (0.8% + 5 digits)
2V
1 mV
± (0.8% + 5 digits)
20V
0.01V
± (0.8% + 5 digits)
200V
0.1V
± (0.8% + 5 digits)
750V
1V
± (0.8% + 5 digits)



Maximum input voltage: 750V AC
Frequency range: 40 ... 400 Hz
Conversion RMS



DC

Measuring range
Resolution
Accuracy
200 mV
0.1 mV
± (0.5% + 5 digits)
2V
1 mV
± (0.5% + 5 digits)
20V
0.01V
± (0.5% + 5 digits)
200V
0.1V
± (0.5% + 5 digits)
1000V
1V
± (0.8% + 5 digits)



Maximum input voltage: 1000V DC

Alternating current

Measuring range
Resolution
Accuracy
200 μA
0.1 μA
± (1.5% + 5 digits)
2000 μA
1 μA
± (1.5% + 5 digits)
20-mA
0.01-mA
± (1.5% + 5 digits)
200-mA
0.1-mA
± (1.5% + 5 digits)
2 A
0.001 A
± (3.0% + 5 digits)
20 A
0.01A
± (3.0% + 5 digits)



Overload protection at μA, mA: 200-mA / 1000V fuse
Overload protection at A: 10 A / 500V fuse
maximum input current μA: 2000 μA
maximum input current mA: 200-mA
maximum input current A: 10 A.
Frequency range: 40 ... 400 Hz
Conversion RMS

Measuring function

Direct current

Measuring range
Resolution
Accuracy
200 μA
0.1 μA
± (1.2% + 5 digits)
2000 μA
1 μA
± (1.2% + 5 digits)
20-mA
0.01-mA
± (1.2% + 5 digits)
200-mA
0.1-mA
± (1.2% + 5 digits)
2 A
0.001 A
± (2.0% + 5 digits)
20 A
0.01A
± (2.0% + 5 digits)



Overload protection at μA, mA: 200-mA / 1000V fuse
Overload protection at A: 10 A / 500V fuse
maximum input current μA: 2000 μA
maximum input current mA: 200-mA
maximum input current A: 10 A.

Measuring function

Resistance

Measuring range
Resolution
Accuracy
200 Ω
0.1 Ω
± (1.0% + 5 digits)
2 kΩ
0.001 kΩ
± (1.0% + 5 digits)
20 kΩ
0.01 kΩ
± (1.0% + 5 digits)
200 kΩ
0.1 kΩ
± (1.0% + 5 digits)
2 MΩ
0.001 MΩ
± (1.0% + 5 digits)
20 MΩ
0.01 MΩ
± (1.0% + 5 digits)



Diode measurement


Measuring range
Resolution
Accuracy
Indicates the forward voltage
1 mV
-



Continuity test


Measuring range
Resolution
Accuracy
Beep at <70 Ω
0.1 Ω
-



Other specifications

Range selection
Automatically and manually
Measurement with receiver
Detecting cable bridges, detecting cable runs
Measurement with network function
Detection of open and closed circuits,

wrong connection, "split pair", "reverse" connection,

Network integration test, screening test
Further measurement function
"NCV" detection, telephone connection testing
Display
LCD, 1999 digits
Overload indicator
"OIL"
Automatic shutdown
After 15 minutes of inactivity
Fuses
F10A / 500V, F200mA / 1000A
Battery indicator
Display when battery is discharged
Power supply
9V block battery
Operating conditions
0 ... 40°C / 32 ... 104°F

-10 ... 50°C / 14 ... 122°F
Dimensions
195 x 92 x 55 mm / 7.7 x 3.6 x 2.2 in
Weight
Approx. 400 g / < 1 lb (with batteries)


DELIVERY SCOPE
1 x Cable detector PCE-LT 12
1 x Receiver
1 x Pair of test leads
1 x Connection adapter strand
2 x 9V block batteries
1 x User manual

Tampilkan Lebih Banyak