Detail Cannon Ravenfield® BS/C+ HTHS Tapered Plug Viscometer N/A
Alat Laboratorium Mikrobiologi
DESKRIPSI
The Ravenfield® HTHS BS/C+ Viscometer by CANNON is a compact, high precision, tapered plug viscometer that measures the high temperature, high shear viscosity of engine lubricants and other oils according to ASTM D4741, CEC L-36-A-90 and IP 370 as specified by SAE J300 and ACEA. The Ravenfield BS/C+ Tapered Plug Viscometer also correlates to ASTM D4683 with no bias and is capable of testing across a wide range of temperatures and shear rates. Also available with an optional Model DR autosampler which permits the testing of up to 22 samples without operator intervention.
SPESIFIKASI
UNIT WEIGHT
Without DR Autosampler: 30.0 kg (66 lb)
With DR Autosampler: 50.0 kg (110 lb)
METHOD
ASTM D4741, SAE J300, IP 370, CEC L-36-A-90
DIMENSIONS (W X D X H)
Without DR Autosampler: 62.2 cm × 38.1
cm × 64.8 cm (24.5 in × 15 in × 25.5 in)
With DR Autosampler: 83.3 cm × 41.9 cm × 64.8 cm (32.8
in × 16.5 in × 25.5 in)
SHIPPING DIMENSIONS (W X D X H)
Without DR Autosampler: 81.0 cm × 92.0
cm × 64.8 cm (31.9 in × 36.2 in × 25.5 in)
With DR Autosampler: 122.0 cm × 92.0 cm × 64.8 cm (48
in × 36.2 in × 25.5 in)
SHIPPING WEIGHT (WITH ALL ITEMS)
Without DR Autosampler: 50.0 kg (110.0 lb)
With DR Autosampler: 70.0 kg (154.2 lb)
MAXIMUM THROUGHPUT
> 12 tests per hour
SAMPLE CAPACITY
1 (without Model DR Autosampler);
22 (with Model DR Autosampler)
VISCOSITY RANGE
Up to 30 mPa·s (cP) depending on
temperature and shear rate
TEMPERATURE RANGE AND ACCURACY
40 °C to
180 °C
Accuracy at 150 °C,± 0.02 °C (viscosity range 1.5 cP to 5.9 cP) at 106 sec-1 shear
rate
Accuracy at 100 °C,± 0.02 °C (viscosity range 4.2 cP to 18.9 cP) at 106 sec-1 shear
rate)
MINIMUM SAMPLE/SOLVENT VOLUME
10 mL
sample/20 mL
solvent per test
OPERATING CONDITIONS
10% to 75% relative humidity,non-condensing,Installation
Category II; Pollution Degree 2
ELECTRICAL SPECIFICATIONS
100/115 Vac,50/60 Hz; 230 Vac,50/60 Hz; 120 watts power consumption
COMPLIANCE
CE Mark; EMC directive (89/336/EC); Low voltage directive
(73/23/EC); HI-POT (1900 Vdc,60 sec.)
SHEAR RATE RANGE
100,000 sec-1
to 2,000,000 sec-1
depending on sample viscosity and temperature
ROTOR HEIGHT ADJUSTMENT
0.002 mm,position
resolution ± 0.01 mm
Alat Laboratorium Umum
Hubungi :
Juni Tarigan (Mr.)
0811 198 0702
Pera (Ms.)
0811 3801 0819
Admin
0813-2310-201
PT. ANDALAN BANGUN SEJAHTERA
Jl. Sumur Batu No. 1, Kemayoran
Jakarta Pusat - Indonesia 10640
Telp : +6221-42803207, 4227517
Fax : +6221-42803208
Tampilkan Lebih Banyak