Current clamp with NCV measurement / Current measurement up to 200 A AC / Frequency measurement directly on the clamp / Ready for immediate use / Simple operation
The current clamp is a multimeter with a variety of different functions. Current measurements up to 200 A AC can be carried out with the current clamp without contact. This current range of the current clamp covers a wide range of current measurements. Thanks to the contactless current measurements of the current clamp, measurements can be made during operation. This means that there is no need to prepare the current clamp for measurement, as measurements can be taken directly on the cable to be measured.
Another special non-contact feature of the current clamp is the NCV (Not Connected Voltage) measurement. With this measurement, the current clamp can indicate whether a voltage is present on a line. Here, too, the current clamp does not need to be prepared for measurement during operation. These two features of the current clamp thus reduce the risk of injury from electric shock.
Other useful functions of the current clamp are the measurement of resistance and the continuity test. The continuity test of the current clamp can be used, for example, to determine whether a relay in a switch box is fully closed. Thanks to the fast measuring frequency of the current clamp, any current fluctuations can be determined. This makes the current clamp an indispensable tool for every electrician.
HIGHLIGHTS
- Inductive current measurement up to 200 A AC
- Voltage measurement with frequency meter
- "Hold" function for freezing the measured value
- Temperature measurement with thermocouple
- Small and compact design
- Smaller internal resistance with the LowZ function
SPECIFICATION
Measuring function
AC / Alternating current
Measuring range
Resolution
Accuracy
200 A
0.1 A
±(3.0 % + 3 digits)
Frequency range: 40 ... 400 Hz
Maximum input current: 200 A AC
Measuring function
DC / Direct current
Measuring range
Resolution
Accuracy
600 µA
0.1 µA
±(1.0 % + 4 digits)
1000 µA
1 µA
±(1.0 % + 4 digits)
Maximum input current: 1000 µA
Measuring function
DC voltage
Measuring range
Resolution
Accuracy
600 mV
0.1 mV
±(0.7 % + 3 digits)
6 V
0.001 V
±(0.7 % + 3 digits)
60 V
0.01 V
±(0.7 % + 3 digits)
600 V
0.1 V
±(0.7 % + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600 V DC AC rms
Measuring function
AC voltage
Measuring range
Resolution
Accuracy
6 V
0.001 V
±(0.8 % + 3 digits)
60 V
0.01 V
±(0.8 % + 3 digits)
600 V
0.1 V
±(0.8 % + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600 V DC AC rms
Frequency range: 40 ... 400 Hz
Measuring function
LowZ AC/DC
Measuring range
Resolution
Accuracy
600 V
0.1 V
±(2.0 % + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600 V DC AC rmsS
Frequency range: 40 ... 400 Hz
Measuring function
Resistance
Measuring range
Resolution
Accuracy
600 Ω
0.1 Ω
±(0.8 % + 3 digits)
6 kΩ
0.001 kΩ
±(0.8 % + 3 digits)
60 kΩ
0.01 kΩ
±(0.8 % + 3 digits)
600 kΩ
0.1 kΩ
±(0.8 % + 3 digits)
6 MΩ
0.001 MΩ
±(1.2 % + 3 digits)
60 MΩ
0.1 MΩ
±(1.2 % + 3 digits)
Test voltage (open circuit): 0.4 V
Surge protection: 250 V AC/DC rms
Measuring function
Continuity test
Measuring range
Resolution
Accuracy
-
0.1 Ω
-
Surge protection: 250 V AC/DC rms
Audible signal at <50 Ω
Measuring function
Diode test
Measuring range
Resolution
Accuracy
-
0.001 V
-
Surge protection: 250 V AC/DC rms
Forward current: 1 mA DC
Forward voltage: 3.3 V DC
Measuring function
Capacitance
Measuring range
Resolution
Accuracy
99.99 nF
0.01 nF
±(4.0 % + 5 digits)
999.9 nF
0.1 nF
±(4.0 % + 5 digits)
9.999 µF
0.001 µF
±(4.0 % + 5 digits)
99.99 µF
0.01 µF
±(4.0 % + 5 digits)
999.9 µF
0.1 µF
±(4.0 % + 5 digits)
9.999 mF
1 µF
±(4.0 % + 5 digits)
99.99 mF
0.01 mF
±(4.0 % + 5 digits)
Surge protection: 250 V AC/DC rms
Measuring function
Temperature (thermocouple type K)
Measuring range
Resolution
Accuracy
-20 ... 0 °C
1 °C
±(3.0 % + 2 digits)
1 ... 400 °C
1 °C
±(2.0 % + 2 digits)
-4 ... 32 °F
1 °F
±(3.0 % + 4 digits)
33 ... 752 °F
1 °F
±(2.0 % + 4 digits)
Surge protection: 250 V AC/DC rms
Measuring function
Frequency (with current clamp)
Measuring range
Resolution
Accuracy
99.99 Hz
0.01 Hz
±(1.5 % + 5 digits)
999.9 Hz
0.1 Hz
±(1.5 % + 5 digits)
>1 kHz
0.001 kHz
for reference only
Frequency range: 10 Hz ... 1 kHz
Maximum input current: 200 A AC rms
Input range: > 60 A AC rms (if the input current increases, the frequency also increases)
Measuring function
Frequency (when measuring voltage)
Measuring range
Resolution
Accuracy
99.99 Hz
0.01 Hz
±(1.5 % + 5 digits)
999.9 Hz
0.1 Hz
±(1.5 % + 5 digits)
9.999 Hz
0.001 kHz
±(1.5 % + 5 digits)
>10 kHz
0.01 kHz
for reference only
Frequency range: 10 Hz ... 10 kHz
Measuring function
Frequency (direct measurement)
Measuring range
Resolution
Accuracy
99.99 Hz
0.01 Hz
±(0.3 % + 5 digits)
999.9 Hz
0.1 Hz
±(0.3 % + 5 digits)
9.999 Hz
1 Hz
±(0.3 % + 5 digits)
99.99 kHz
0.01 kHz
±(0.3 % + 5 digits)
999.9 kHz
0.1 kHz
±(0.3 % + 5 digits)
9.999 kHz
1 kHz
±(0.3 % + 5 digits)
99.99 MHz
0.01 MHz
±(0.3 % + 5 digits)
Measuring range: 10 Hz ... 60 MHz
Input impedance: 10 MΩ
Input range: >0.2 V AC rms (if the input voltage increases, the frequency also increases)
Maximum input voltage: 250 V AC rms
Measuring function
Duty cycle
Measuring range
Resolution
Accuracy
5 ... 95 %
0.1 %
±0.3 %
More specifications
Range selection
automatic and manual
Maximum working height
2000 m / 6561 ft
Display
LC display
Largest display value
5999
Overrange
"OL" display
Underrange
"-OL" display
Measuring rate
3 measurements per second
Automatic shutdown
after 15 minutes of inactivity
Power supply
1 x 9 V block battery
Operating conditions
0 ... 40 °C / 32 ... 104 °F
Storage conditions
-10 ... 50 °C / 14 ... 122 °F
Dimensions
201 x 65 x 43 mm / 7.9 x 2.6 x 1.7"
Weight
ca. 265 g / 9.3 oz (with battery)
DELIVERY SCOPE
1 x Clamp meter PCE-CM 5
1 x Pair of test leads
1 x Transport bag
1 x 9V Bock battery
1 x User manual