Detail Clamp Meter PCE-DC 50
Clamp Meter PCE-DC 50
Instrument Laboratorium
Deskripsi produk
DESCRIPTION
Clamp meter PCE-DC 50
Clamp meter with true rms measurement / AC current measurement / Voltage measurement / Temperature measurement / Bluetooth interface / Rubberized housing / Display hold / Automatic switch-off / Test lead max. 48 mm / Many measuring functions
The clamp meter PCE-DC 50 is a measuring device for measuring currents of up to 1000 A AC / DC. In addition to current measurement, the clamp can also measure and test voltage, frequency, duty cycle, resistance, continuity test, capacitors and diodes. The enclosure diameter of the clamp is 48 mm. Thus, you can also perform measurements on cables with a large cross-section. Thanks to the NCVD function, it is possible to use the measuring clamp to check contactlessly whether a voltage is applied to a cable.
This clamp has an integrated Bluetooth interface. Via this Bluetooth interface a connection to the PC or the smartphone can be established with the measuring pliers. This allows the measured data of the measuring clamp to be stored and analyzed. If the PC does not have a Bluetooth interface to connect the measuring pliers, a suitable Bluetooth adapter is included in the delivery.
Another special feature of the measuring clamp is the measurement of temperatures. Two type-K thermocouples can be connected to the measuring clamp and read out at the same time. Here, temperatures of up to 1000°C / 1832°F can be measured. The housing of the measuring pliers consists of a robust plastic, which is additionally coated with a rubber coating. Thanks to the additional rubber coating, the measuring pliers can easily withstand impacts.
HIGHLIGHTS
- Sample rate 2 Hz
- Cover on the test sockets
- AC A and AC V measurement
- Bluetooth interface
- Cable diameter max. 48 mm
- Temperature measurement via 2 thermocouples
- Automatic shutdown
- Non-contact voltage detection
SPECIFICATION
Current measurement DC A
Measuring range
Resolution
Accuracy (of rdg.)
500 μA
0.01 μA
± (1% + 6 digits)
5000 μA
0.1 μA
± (1% + 6 digits)
50 A
0.01A
± (2.5% + 5 digits)
1000 A
0.1 A
± (2.5% + 30 digits)
Current measurement AC A
Measuring range
Resolution
Accuracy (of rdg.)
500 μA
0.01 μA
± (1.5% + 30 digits)
5000 μA
0.1 μA
± (1.5% + 30 digits)
50 A
0.01A
± (2.5% + 30 digits)
1000 A
0.1 A
± (2.8% + 30 digits)
Note: For AC A measurements, the specification of accuracy refers to the range of 5% to 100% of the measuring range
Resistivity
Measuring range
Resolution
Accuracy (of rdg.)
500 Ω
0.01
± (1% + 9 digits)
5 kΩ
0.0001
± (1% + 5 digits)
50 kΩ
0.001
± (1% + 5 digits)
500 kΩ
0.01
± (1% + 5 digits)
5 MΩ
0.0001
± (3% + 10 digits)
50 MΩ
0.001
± (3.5% + 10 digits)
Voltage measurement DC V
Measuring range
Resolution
Accuracy (of rdg.)
500 mV
0.01 mV
± (0.1% + 8 digits)
5V
0.0001V
± (0.1% + 4 digits)
50V
0.001 V
± (0.1% + 4 digits)
500V
0.01V
± (0.1% + 4 digits)
600V
0.1V
± (0.5% + 4 digits)
Voltage measurement AC V (50 Hz ... 1000 Hz)
measuring range
Resolution
Accuracy (of rdg.)
500 mV
0.01 mV
± (0.8% + 9 digits) (at 50 Hz / 60 Hz)
5V
0.0001V
± (1% + 30 digits)
50V
0.001 V
± (1% + 30 digits)
500V
0.01V
± (1% + 30 digits)
600V
0.1V
± (1% + 30 digits)
Note: The accuracy specification for AC V measurements refers to the range of 5% to 100% of the measuring range
Capacitance measurement
Measuring range
Resolution
Accuracy (of rdg.)
500 nF
0.01
± (3.5% + 40 digits)
5000 nF
0.1
± (3.5% + 10 digits)
50 μF
0.001
± (3.5% + 10 digits)
500 μF
0.01
± (3.5% + 10 digits)
5mF
0.0001
± (5% + 10 digits)
Frequency measurement
Measuring range
Resolution
Accuracy (of rdg.)
50 Hz
0.001
± (0.3% + 2 digits)
500 Hz
0.01
± (0.3% + 2 digits)
5 kHz
0.0001
± (0.3% + 2 digits)
50 khz
0.001
± (0.3% + 2 digits)
500 kHz
0.01
± (0.3% + 2 digits)
5 Mhz
0.0001
± (0.3% + 2 digits)
10 MHz
0.001
± (0.3% + 2 digits)
Duty cycle
Measuring range
Resolution
Accuracy (of rdg.)
5% ... 95%
0.1
± (1% + 2 digits) (of the measured value)
Pulse width: 100 μs ... 100 ms
Frequency: 10 Hz ... 10 kHz
Temperature
Measuring range
Resolution
Accuracy (of rdg.)
-100°C ... 1000°C / -148 ... 1832°F
0.1
± (1% + 2.5°C / 4.5°F)
General technical data
Conductor diameter
Max. 48 mm
Display
Two lines 50,000 digits
Continuity test
50 ohms / < 50-mA
Diode test
0.3-mA / 2.8V DC
Battery indicator
Battery icon when battery low
Overrange
OL, if measuring range exceeded
Sample rate
2 Hz
Interface
Bluetooth
Peak detection
> 1 ms
Thermocouple
Type K
Fuse
500-mA ceramic quick-acting
AC bandwidth (AC A / AC V)
50 Hz ... 400 Hz
AC measurement
True RMS
Operating conditions
5°C ... 40°C / 41 ... 104°F, max. 80% RH at 31°C
Storage conditions
-20°C ... 60°C / -4 ... 140°F, max. 80% rh
Power supply
9V block battery
Automatic shutdown
After about 30 minutes
Dimensions (W x H x D)
230 x 76 x 40 mm / 9 x 3 x 1.6 in
Weight
315 g / < 1 lb
Security
IEC 1010-1 (2001):
EN 61010-1 (2001)
CAT III 600V
CAT II 1000V
Degree of pollution 2
DELIVERY SCOPE
1 x Clamp meter PCE-DC 50
1 x Test lead set
1 x Transport case
1 x PC software
1 x Bluetooth adapter
2 x Thermocouples type-K
1 x 9V block battery
Tampilkan Lebih Banyak