Back to Top

1
Hi, Guest!

Clamp Meter PCE-PCM 3

Update Terakhir
:
13 / 09 / 2024
Min. Pembelian
:
1 Unit

Harga

Rp. 100
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail Clamp Meter PCE-PCM 3


Clamp Meter PCE-PCM 3
Instrument Laboratorium

Deskripsi produk
DESCRIPTION
Clamp meter PCE-PCM 3
Digital multimeter for single-phase measurement / NCV measurement / W / VA / Var / Inrush Current / 1000 A AC Current Measurement / Bluetooth Interface / Frequency Measurement / Backlight / Voltage measurement / 750 kW power

With the clamp meter AC currents of up to 1000 A AC can be measured easily. At the same time, voltages of up to 1000V AC / DC can be measured with the clamp meter. Thus, with the power current clamp, apparent power, reactive power and active power measurements up to 750 KW are possible. Another function of the clamp meter is the measurement of the inrush current. Many consumers have a tremendously high current at the moment of switch-on. With a conventional clamp meter such a measurement is not possible. For the clamp meter this is not a problem.

With the NCV (Not Connected Voltage) function of the clamp meter, it can be checked whether a voltage is applied to a line without performing a contacting measurement. This makes the work much easier for the user thanks to the clamp meter. In addition to the measuring function, the clamp meter can also be connected to a terminal via the Bluetooth interface. Via this Bluetooth interface, the measured data can be transmitted directly from the clamp meter to the terminal, where it can be logged, analyzed and sent.
HIGHLIGHTS
- Apparent / active / reactive power
- Measurement up to the 20th harmonic
- "Not Connected Voltage" function
- Inrush current measurement
- Current measurement up to 1000 A AC
- Bluetooth interface

SPECIFICATION
Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH
Measuring function


Current measurement AC


Measuring range
Resolution
Accuracy
60 A
0.01 A
± 2% + 8 Dgt
600 A
0.1 A
± 2% + 8 Dgt
1000 A
1 A
± 2% + 8 Dgt



Maximum input current: 1000 A AC
Frequency range: 40 .... 400 Hz



Measuring function


Inrush current AC


Measuring range
Resolution
Accuracy
60 A
0.01 A
For reference only
600 A
0.1 A
± 5% + 60 Dgt
1000 A
1 A
± 5% + 60 Dgt



Integral time: 100 ms

Measuring range: 20 ... 1000 A

Frequency range: 40 .... 400 Hz



Measuring function


Voltage measurement DC


Measuring range
Resolution
Accuracy
6V
0.001V
± 0.5% + 5 Dgt
60V
0.01V
± 0.5% + 5 Dgt
600V
0.1V
± 0.5% + 5 Dgt
1000V
1V
± 0.8% + 4 Dgt



Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC



Measuring function


Voltage measurement AC


Measuring range
Resolution
Accuracy
6V
0.001V
± 0.6% + 4 Dgt
60V
0.01V
± 0.6% + 4 Dgt
600V
0.1V
± 0.6% + 4 Dgt
1000V
1V
± 0.8% + 4 Dgt



Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC
Frequency range: 40 ... 400 Hz



Measuring function


Frequency measurement with


The current measuring function


Measuring range
Resolution
Accuracy
99.99 Hz
0.01 Hz
± 1.5% + 5 Dgt
999.9 Hz
0.1 Hz
± 1.5% + 5 Dgt



Measuring range: 10 ... 1 kHz
Measuring range of the input signal: > 20 AAC (rms value)
The input current increases with the measuring frequency.
Maximum input current: 1000 AAC (rms value)



Measuring function


Frequency measurement with the


Voltage measurement function


Measuring range
Resolution
Accuracy
99.99 Hz
0.01 Hz
± 1.5% + 5 Dgt
999.9 Hz
0.1 Hz
± 1.5% + 5 Dgt
9,999 kHz
0.001 kHz
± 1.5% + 5 Dgt



Measuring range: 10 ... 10 kHz
Measuring range of the input signal: > 1V AC (rms value)
The input current increases with the measuring frequency.
Maximum input voltage: 1000V AC (rms value)



Measuring function


Frequency measurement


Measuring range
Resolution
Accuracy
9,999 Hz
0.001 Hz
± 0.3% + 5 Dgt
99.99 Hz
0.01 Hz
± 0.3% + 5 Dgt
9,999 kHz
0.1 Hz
± 0.3% + 5 Dgt
999.9 Hz
0.001 kHz
± 0.3% + 5 Dgt
99.99 kHz
0.01 kHz
± 0.3% + 5 Dgt
999.9 kHz
0.1 kHz
± 0.3% + 5 Dgt
9,999 MHz
0.001 MHz
± 0.3% + 5 Dgt



Overvoltage protection: 1000V DC or 750V AC (rms value)
Range of voltage input> 2V
(as the input voltage increases, so does the frequency)



Measuring function


Duty cycle


Measuring range
Resolution
Accuracy
0.1 ... 99.9%
0.1%
± 0.3% + 5 Dgt



Frequency range: 10 ... 10 kHz
Voltage range: 2 ... 250V AC (rms value)
(The voltage increases with the frequency)

Duty cycle with the
Frequency range: 10 ... 1 kHz
Current measurement function
Input current: 20 ... 1000 AAC (rms value)

Duty cycle with the
Frequency range: 10 ... 1 kHz
Voltage measurement function
Input current: 1 ... 750V AC (rms value)

Input impedance: 1MΩ



Measuring function


Resistivity


Measuring range
Resolution
Accuracy
600 Ω
0.1 Ω
± 0.8% + 3 Dgt
6 kΩ
0.001 kΩ
± 0.8% + 3 Dgt
60 kΩ
0.01 kΩ
± 0.8% + 3 Dgt
600 kΩ
0.1 kΩ
± 0.8% + 3 Dgt
6 MΩ
0.001 MΩ
± 2% + 5 Dgt
60 MΩ
0.1 MΩ
± 2% + 5 Dgt



Measuring voltage: approx. 0.78V
Overvoltage protection: 750V DC, 1000V AC (rms value)



Measuring function


Continuity test


Measuring range
Resolution
Accuracy
600 Ω
0.1 Ω
-



Acoustic signal at < 50 Ω
Test voltage: 1.48V
Overvoltage protection: 750V DC, 1000V AC (rms value)



Measuring function


Capacitance measurement


Measuring range
Resolution
Accuracy
9.999 nF
0.001 nF
± 3% + 5 Dgt
99.99 n.f.
0.01 nF
± 3% + 5 Dgt
999.9 nF
0.1 nF
± 3% + 5 Dgt
9.999 μF
0.001 μF
± 3% + 5 Dgt
99.99 μF
0.01 μF
± 3% + 5 Dgt
999.9 μF
0.1 μF
± 3% + 5 Dgt
9,999mF
0.001 mF
± 3% + 5 Dgt
99.99 mF
0.01 mF
± 3% + 5 Dgt



Overvoltage protection: 750V DC, 1000V AC (rms value)



Measuring function


Diode measurement


Measuring range
Resolution
Accuracy
3V
0.001V
-



DC anode side: approx. 1-mA
DC cathode side: approx. 3.2V
Overvoltage protection: 750V DC, 1000V AC (rms value)



Measuring function


Single phase power measurement


Measuring range
Resolution
Accuracy
3 W / VA / Var
0.01 W / VA / Var
± 3% + 5 Dgt
100 W / VA / Var
0.1 W / VA / Var
± 3% + 5 Dgt
4000 W / VA / Var
1 W / VA / Var
± 3% + 5 Dgt
10 kW / VA / var
0.01 kW / VA / Var
± 3% + 5 Dgt
100 kW / VA / var
0.1 kW / VA / Var
± 3% + 5 Dgt
750 kW / VA / var
1 kW / VA / Var
± 3% + 5 Dgt


Tampilkan Lebih Banyak
Kontak Kami