Ultrasonic flowmeter with 32 GB data memory / measuring range ±32 m/s /
reproducibility ±0.5 % of measured value / different measuring probes / alarm limit values /
2.8 " LC display / for all media
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the Clamp-on Ultrasonic Flow Meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the Clamp-on Ultrasonic Flow Meter. The installation aid graphically displays the signal quality of the Clamp-on Ultrasonic Flow Meter. In addition, it is graphically displayed whether the sensors of the Clamp-on Ultrasonic Flow Meter are positioned at the correct distance from each other. To carry out flow measurements with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The Clamp-on Ultrasonic Flow Meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values via the data logger function of the Clamp-on Ultrasonic Flow Meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the Clamp-on Ultrasonic Flow Meter. A memory point of the Clamp-on Ultrasonic Flow Meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the Clamp-on Ultrasonic Flow Meter. 10 million measuring points can be stored on the Clamp-on Ultrasonic Flow Meter.
With the optional software, the recorded measured values can be read out from the Clamp-on Ultrasonic Flow Meter. For analysis, the measured values from the Clamp-on Ultrasonic Flow Meter can be displayed in tabular and graphic form. For further processing of the measured values from the Clamp-on Ultrasonic Flow Meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the Clamp-on Ultrasonic Flow Meter can be set via the software. A live view of the measured values from the Clamp-on Ultrasonic Flow Meter is also possible with the software.
In order to determine the amount of heat with the Clamp-on Ultrasonic Flow Meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the Clamp-on Ultrasonic Flow Meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the Clamp-on Ultrasonic Flow Meter can determine the amount of heat. If required, the Clamp-on Ultrasonic Flow Meter can calculate and display the costs per unit of heat simultaneously during the measurement. Thus, the Clamp-on Ultrasonic Flow Meter is used, for example, in the inspection of heating systems.
The LC colour display of the Clamp-on Ultrasonic Flow Meter has a size of 2.8" and is therefore easy to read.
PCE-TDS 200 M SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the Clamp-on Ultrasonic Flow Meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the Clamp-on Ultrasonic Flow Meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.
HIGHLIGHTS
- Messbereich ±32 m/s
- USB-C Schnittstelle zur Datenübertragung
- optionale Software zur Analyse der Messwerte
- Reproduzierbarkeit ±0,5 % vom Messwert
- Wärmemengenmessung
- Datenspeicher für 10 Millionen Messpunkte
- individuell einstellbare Alarmgrenzwerte
SPECIFICATION
Flow measurement
Measuring range
±32 m/s
Accuracy
0,001 m/s
Genauigkeit
DN ≥50 mm: ±1.5 % rdg. for velocities > 0.3 m/s
DN <50 mm: ±3.5 % rdg. for velocities > 0.3 m/s
Reproducibility
±0.5 % of measured value
PCE-TDS 200 M SENSOR
Sensor pair
Pipe diameter
DN 50 ... 700 / 57 ... 720 mm
Temperature resistance
-30 ... 160 °C
Dimension
45 x 30 x 30 mm
PCE-TDS 200 L SENSOR
Pipe diameter
DN 300 ... 6000 mm
Temperature resistance
-30 ... 160 °C
Dimension
91 x 52 x 44 mm
Measuring method
Z, V, N, W
Medium
- water
- sea water
- oil
- crude oil
- methanol
- ethanol
- diesel
- petrol
- petroleum
- user defined
(manual input of the sound velocity from the medium)
All liquids with an impurity
<5 %
Pipe material
- copper CU
- steel FE
- stainless steel VA
- aluminium AL
- brass ME
- cast iron CI
- iron FE
- nickel NI
- titanium TI
- zink ZI
- acrylic AC
- polyethylene PE
- polypropylene PP
- polyvinyl chloride PVC
- nylon NY
- user defined
(manual input of the transversal sound velocity
of the pipe material)
Inner pipe lining
- no lining
- user defined
Tampilkan Lebih Banyak