Detail Current Clamp PCE-DC 25
Current Clamp PCE-DC 25
Instrument Laboratorium
Deskripsi produk
DESCRIPTION
Current clamp with Bluetooth interface / Current measurement 0 ... 1000 A AC/DC / Temperature measurement / NCV test / Clamp opening 34 mm (1.3") / Measuring rate of 3 Hz /
Optionally expandable with Rogowski coil for 3000 A AC / Automatic switch-off
The current clamp has a measuring range of 0… 1000 A AC/DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1.2") can be connected to the clamp meter. With the optional Rogowski coil, the measuring range of the clamp meter can be extended to up to 3000 A AC. The clamp meter has sub-functions for current measurement. The inrush current can be measured with the clamp meter. This is a particularly important function, as motors such as those installed in ventilation systems or hall lighting require a particularly high current when switched on.
In addition to current measurement, the current clamp can also measure voltages from 0… 1000 V AC/DC, resistances, frequencies and capacitances. The functions can be set using the rotary selector switch on the clamp meter. With the NCV function, the clamp meter can be used to determine the absence of voltage without contact. As soon as a voltage of 150 V AC is applied, this is indicated by an additional red LED. This function is active for every measuring function selected using the rotary selector switch. An LED lamp is integrated in the clamp meter for optimal illumination of the measuring point.
The current clamp can be connected to an Android or iOS device via the Bluetooth interface. With the free app for the clamp meter, the measured values can be displayed, saved and further processed. The clamp meter thus covers a wide range of measuring tasks due to the multitude of functions.
HIGHLIGHTS
- Measuring range 0 ... 1000 A AC/DC
- Bluetooth interface
- Inrush current measurement
- Not Connected Voltage function
- LC colour display
- Optionally with ISO certificate
SPECIFICATION
DC voltage
Measuring range
600.0 mV DC
Resolution
0.1 mV DC
Accuracy
±(0.5 % + 8 digits)
Measuring range
6.000 V DC
Resolution
0.001 V DC
Accuracy
±(1.5 % + 5 digits)
Measuring range
60.00 V DC
Resolution
0.01 V DC
Accuracy
±(1.5 % + 5 digits)
Measuring range
600.0 V DC
Resolution
0.1 V DC
Accuracy
±(1.5 % + 5 digits)
Measuring range
1000 V DC
Resolution
1 V
Accuracy
±(1.5 % + 5 digits)
Input impedance
>10 MΩ
Overvoltage protection
1000 V AC/DC
AC voltage
Measuring range
6.000 V AC
Resolution
0.001 V AC
Accuracy
±(1.5 % + 5 digits)
Measuring range
60.00 V AC
Resolution
0.01 V AC
Accuracy
±(1.5 % + 5 digits)
Measuring range
600.0 V AC
Resolution
0.1 V AC
Accuracy
±(1.5 % + 5 digits)
Measuring range
1000 V AC
Resolution
1 V AC
Accuracy
±(1.5 % + 5 digits)
Peak value (PEAK) accuracy
±10 %
Peak value (PEAK) response time
1 ms
Input impedance
>10 MΩ
Overvoltage protection
1000 V AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Low pass filter (LowZ)
(50 ... 400 Hz)
Measuring range
6.000 V AC
Resolution
0.001 V AC
Accuracy
±(3.0 % + 40 digits)
Measuring range
60.00 V AC
Resolution
0.01 V AC
Accuracy
±(3.0 % + 40 digits)
Measuring range
300.0 V AC
Resolution
0.1 V
Accuracy
±(3.0 % + 40 digits)
Input impedance
<300 kΩ
Overvoltage protection
1000 V AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
AC with DC voltage
(50 ... 400 Hz)
Measuring range
6.000 V AC
Resolution
0.001 V AC
Accuracy
±(2.5 % + 20 digits)
Measuring range
60.00 V AC
Resolution
0.01 V AC
Accuracy
±(2.5 % + 20 digits)
Measuring range
600.0 V AC
Resolution
0.1 V AC
Accuracy
±(2.5 % + 20 digits)
Measuring range
1000 V AC
Resolution
1 V AC
Accuracy
±(2.5 % + 20 digits)
Input impedance
>10 MΩ
Direct current
Measuring range
600.0 A DC
Resolution
0.1 A DC
Accuracy
±(2.5 % + 5 digits)
Measuring range
1000 A DC
Resolution
1 A DC
Accuracy
±(2.8 % + 5 digits)
Overvoltage protection
1000 A DC
Alternating current
(50 ... 60 Hz)
Measuring range
600.0 A AC
Resolution
0.1 A AC
Accuracy
±(2.5 % + 5 digits)
Measuring range
1000 A AC
Resolution
1 A AC
Accuracy
±(2.8 % + 5 digits)
Overload protection
1000 A AC/DC
Flexible clamp meter
(50 ... 400 Hz)
Measuring range
30.00 A AC
Resolution
0.01 A AC
Accuracy
±(3.0 % + 5 digits)
Measuring range
300.0 A AC
Resolution
0.1 A AC
Accuracy
±(3.0 % + 5 digits)
Measuring range
3000 A AC
Resolution
1 A AC
Accuracy
±(3.0 % + 5 digits)
Overload protection
3000 A AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Resistance
Measuring range
600.0 Ω
Resolution
0.1 Ω
Accuracy
±(1.0 % + 10 digits)
Measuring range
6.000 kΩ
Resolution
0.001 kΩ
Accuracy
±(1.5 % + 5 digits)
Measuring range
60.00 kΩ
Resolution
0.01 kΩ
Accuracy
±(1.5 % + 5 digits)
Measuring range
600.0 kΩ
Resolution
0.1 kΩ
Accuracy
±(1.5 % + 5 digits)
Measuring range
6.000 MΩ
Resolution
0.001 MΩ
Accuracy
±(2.5 % + 5 digits)
Measuring range
60.00 MΩ
Resolution
0.01 MΩ
Accuracy
±(3.5 % + 10 digits)
Overvoltage protection
1000 V AC/DC
Continuity test
Signal
<50 Ω
Overvoltage protection
1000 V AC/DC
Diode test
Test current
<1.5 mA
Maximum tension when open
circuit
3.3 V DC
Frequency measurement
Measuring range
9.999 Hz ... 99.99 kHz
Resolution
0.01 ... 10 Hz
Accuracy
±(1.2 % + 5 digits)
Overvoltage protection
1000 V AC/DC
Sensitivity
>5 Vrms with one duty cycle
from 20 ... 80 %
Duty cycle
Measuring range
10.0 ... 90.0 %
Resolution
0.1 %
Accuracy
±(1.2 % + 8 digits)
Pulse range
40 Hz ... 10 kHz
Pulse amplitude
±5 V (0.1 ... 100 ms)
Capacity
Measuring range
60.00 nF
Resolution
0.01 nF
Accuracy
±(4.0 % + 20 digits)
Measuring range
600.0 nF
Resolution
0.1 nF
Accuracy
±(3.0 % + 8 digits)
Measuring range
6.000 µF
Resolution
0.001 µF
Accuracy
±(3.0 % + 8 digits)
Measuring range
60.00 µF
Resolution
0.01 µF
Accuracy
±(3.0 % + 8 digits)
Measuring range
600.0 µF
Resolution
0.1 µF
Accuracy
±(3.0 % + 8 digits)
Measuring range
6000 µF
Resolution
1 µF
Accuracy
±(5.0 % + 8 digits)
Measuring range
60.00 mF
Resolution
0.01 mF
Accuracy
±(5.0 % + 20 digits)
Measuring range
100.0 mF
Resolution
0.1 mF
Accuracy
±(5.0 % + 20 digits)
Overvoltage protection
1000 V AC/DC
Temperature measurement
(Thermocouple Type K)
Measuring range
-40 ... 600.0 °C
Resolution
0.1 °C
Accuracy
±(1.5 % + 5 digits)
Measuring range
600 ... 1000 °C
Resolution
1 °C
Accuracy
±(1.5 % + 5 digits)
Measuring range
-40 ... 600.0 °F
Resolution
0.1 °F
Accuracy
±(1.5 % + 9 digits)
Measuring range
600 ... 1800 °F
Tampilkan Lebih Banyak