DESCRIPTION
Earth Tester with Carrying Strap / Fast Testing on Fixed Installations / Insulation Resistance / Fault Loop Impedance / Switchable Test Voltages and Fault Currents / Menu Languages: German and English
The earth tester is a multifunctional instrument designed for testing electrical safety in accordance with standards EN 61557 and DIN VDE 0100. It offers many functions specifically designed for the inspection and evaluation of electrical installations. The earth tester can perform precise measurements of insulation resistance between live parts and grounding. In the RCD test, both Type-A and AC, B, B+, and F-controlled residual current circuit breakers can be efficiently tested, ensuring the proper functioning of these vital protective devices.

The earth tester allows for quick and accurate measurement of loop resistance to ensure that, in the event of a fault current, there is sufficient resistance to ensure a safe shutdown. Additionally, measuring the protective conductor resistance allows for checking the continuity of conductors and connections. A graphical representation of the wiring helps the operator perform measurements accurately.


The brightness of the display can be adjusted in 4 levels. An adjustable alarm tone warns of errors or exceeding the limit. The adjustable auto-off time of the earth tester prevents accidental battery discharge. The device comes with test leads that meet the specific requirements of CAT III / 600 V and CAT IV / 300V. The earth tester offers a user-friendly interface, clear display elements, and a robust construction to meet the demands in various environments. By complying with international standards, it ensures a safe and reliable assessment of electrical installations according to the highest industry standards.
With our optional EVSE test adapters, tests can also be conducted on wall boxes and charging stations for electric vehicles.
HIGHLIGHTS
- Testing according to EN 61557 and DIN VDE0100
- Insulation resistance
- RCD Type A, AC, B, B+, and F
- Line and fault loop impedance
- Continuity test
- Voltage, phase rotation, and frequency
- Testing of EV charging stations with optional test adapter
- Includes test leads and carrying case

SPECIFICATION
AC voltage AC

Measuring range
0 V ... +550 V
Resolution
1 V
Accuracy
±(2 % v. Mw. + 2 digits)


Isolation resistance

Test voltage DC
50 V
Measuring range
0.1 M Ω . .. +80 M Ω
Resolution
0.001 MΩ (0.100 ... 1.999)
0.01 MΩ (2.00 ... 80.00)
Accuracy
±(5 % v. Mw. + 3 digits)


Isolation resistance

Test voltage DC
100 V, 250 V
Measuring range
0.1 M Ω . .. +199.9 M Ω
Resolution
0.001 MΩ (0.100 ... 1.999)
0.01 MΩ (2.00 . .. 99.99)
0.1 MΩ (100.0 ... 199.9)
Accuracy
±(5 % v. Mw. + 3 digits)


Isolation resistance

Test voltage DC
500 V, 1000 V
Measuring range
0.1 M Ω . .. +199.9 M Ω
Resolution
0.001 MΩ (0.100 ... 1.999)
0.01 MΩ (2.00 . .. 99.99)
0.1 MΩ (100.0 ... 199.9)
Accuracy
±(2 % v. Mw. + 3 digits)


Isolation resistance

Test voltage DC
500 V, 1000 V
Measuring range
+200 M Ω . .. +999 M Ω
Resolution
1 MΩ
Accuracy
±(10 % of Mw. )


Passage test

Measuring range
0.1 Ω . .. +20 Ω
Resolution
0.01 Ω
Accuracy
±(3 % v. Mw. + 3 digits)


passage test

measurement range
+20 Ω . .. +1999 Ω
Resolution
0.1 Ω (20.0 Ω ... 99.9 Ω)
1 Ω (100 Ω ... 1999 Ω)
Accuracy
±(5 % v. Mw. )


Impedance

Measurement range
0.25 Ω . .. +9999 Ω
Resolution
0.01 Ω (0.20 ... 19.99)
0.1 Ω (20.0 . .. 99.9)
1 Ω (100 ... 9999)
Accuracy
±(5 % v. Mw. + 5 digits)


Frequency

Measurement range
+10 Hz . .. +499.9 Hz
Resolution
0.1 Hz
Accuracy
0.2 % + 1 digit


General technical data

Display type
TFT color display
Display size
3.3 inch
Standard(s)
EN61557, DIN VDE 0100
Operating time
15 h
Automatic switch-off adjustable
0. 5 ... 60 min.
Automatic switch-off can be deactivated
Yes
RCD test current characteristic
A, AC, B, B+, F
RCD tripping current
650 mA, 500 mA, 30 mA, 6 mA, 300 mA, 10 mA, 1000 mA, 100 mA
RCD tripping time
0 . .. 500 ms
Touch voltage
0 ... 99. 9 V
Menu language
German, English
Power supply
Battery, Power supply
Weight
1300 g
Device weight with scope of delivery
2165 g
Device weight with scope of delivery and packaging
2300 g
Dimensions (L x W x H)
250 x 135 x 107 mm
Operating conditions
0 ... 40 °C , 95 % r.H
Storage conditions
-10 ... 70 °C , 90 % r. F

DELIVERY SCOPE
1 x Earth Tester PCE-ITE 55B
1 x Test Cable for EU Schuko sockets
3 x Test Leads 1m
3 x Test Probes
3 x Crocodile Clips
1 x Carrying Strap
6 x 1.5V AA Batteries
1 x Factory Calibration Certificate
1 x User Manual