Detail HI 902C Automatic Titration System Automatic Loading System

HI 902C Automatic Titration System

H Specifications

PH RANGE PH RESOLUTION PH ACCURACY (@25ºC/77ºF) PH CALIBRATION
-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
0.1; 0.01; 0.001 pH
±0.001 pH
up to five-point calibration, eight standard buffers and five custom buffers

mV Specifications

MV RANGE MV RESOLUTION MV ACCURACY (@25ºC/77ºF) MV CALIBRATION
-2000.0 to 2000.0 mV
0.1 mV
±0.1 mV
single-point offset

ISE Specifications

ISE RANGE ISE RESOLUTION ISE ACCURACY ISE CALIBRATION
1•10⁻⁶ to 9.99•10¹⁰
1; 0.1; 0.01
±0.5% monovalent; ±1% divalent
up to five-point calibration, seven standard solutions and five user-defined standards

Temperature Specifications

TEMPERATURE RANGE TEMPERATURE RESOLUTION TEMPERATURE ACCURACY (@25ºC/77ºF) TEMPERATURE COMPENSATION
-5.0 to 105.0°C; 23.0 to 221.0°F; 268.2 to 378.2K
0.1°C; 0.1°F; 0.1K
±0.1°C; ±0.2°F; ±0.1K, excluding probe error
manual (MTC) or automatic (ATC)

Additional Specifications

PROGRAMMABLE STIRRER DISPLAY BURETTE SIZES BURETTE RESOLUTION DISPLAY RESOLUTION DOSING ACCURACY METHODS BURETTE AUTO-DETECTION FLOW RATE ENDPOINT DETERMINATION POTENTIOMETRIC TITRATIONS MEASUREMENT UNITS REAL-TIME & STORED GRAPHS USB HOST (SIDE) PERIPHERALS (REAR) GLP CONFORMITY LANGUAGES OPERATING ENVIRONMENT STORAGE ENVIRONMENT POWER SUPPLY DIMENSIONS WEIGHT
propeller type, 100 to 2500 rpm, resolution 100 rpm
5.7” (320 x 240 pixel) backlit color LCD
5, 10, 25, and 50 mL
1/40000
0.001 mL
±0.1% of full burette volume
up to 100 methods (standard and user-defined)
burette size is automatically recognized when inserted into the unit
user-selectable from 0.1 mL/min to 2 x burette volume/min
equivalence point (1st or 2nd derivative) or fixed pH/mV value
acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric
user-specified expression of concentration units to suit specific calculation requirements
mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode: pH/mV/concentration versus time
flash drive compatibility for transfer of methods and reports
connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232, interface for autosampler
instrumentation data storage and printing capabilities
English, Portuguese, Spanish
10 to 40°C (50 to 104°F), up to 95% RH
-20 to 70°C (-4 to 158°F), up to 95% RH
100-240 VAC; "-01" models, US plug (type A); "-02" models, European plug (type C)
390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)
approximately 9 kg (20 lbs.) (with one pump, stirrer and sensors)