Back to Top

1
Hi, Guest!
  • HI98197 Ultra Pure Water EC/ Resistivity Waterproof Portable Meter

HI98197 Ultra Pure Water EC/ Resistivity Waterproof Portable Meter

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail HI98197 Ultra Pure Water EC/ Resistivity Waterproof Portable Meter

The HI98197 is a rugged portable EC/ TDS/ Resistivity/ Salinity meter with the performance and features of a benchtop. The HI98197 is supplied complete with all accessories necessary to perform high purity water measurements packaged into a durable carrying case. The accessories include a stainless steel flow cell and a threaded four ring conductivity probe that allows for high resolution 0.001 ¼ S/ cm for conductivity and 0.1 M© * cm for resistivity readings. Details The HI98197 is supplied with a specialized HI763123 four-ring conductivity probe that not only allows for a 0.001 ¼ S/ cm resolution measurement but also has screw type threads for insertion into the HI605453 AISI 316 stainless steel flow cell. The HI763123 has a built-in temperature sensor and a adjustable temperature coefficient for accurate readings that cover a complete range with a single sensor. The four-ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763123 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove. H+ High purity water used in power generation, semiconductor manufacturing and other industries can be difficult to measure can be difficult to measure due the ability of carbon dioxide ( CO2) to diffuse into water and forming carbonic acid ( H2CO3) . The carbonic acid will dissociate into hydrogen ions ( H+ ) and bicarbonate ions ( HCO3) . These ions will increase the conductivity and decrease the resistivity of the water. In order to measure high purity water accurately it is necessary to perform a continuous flow measurement. The HI98197 uses the HI763123 four ring probe with a threaded connection that is screwed into a stainless steel body flow cell. The flow cell is connected to a water source to determine the conductivity or resistivity whichever is preferred. The HI98197 is an ideal meter for monitoring the mixed bed resin or equivalent system that produces high purity water of 18.2 M© * cm at 25 ° C. Expanded Ranges - HI98197 has an expanded conductivity range from 0.000 ¼ S/ cm to 1000 mS/ cm actual conductivity ( 400 mS/ cm temperature compensated) . The HI98197 also has ranges for TDS, resistivity and three salinity scales. This meter automatically recognizes the probe type ( two or four ring) and allows the user to adjust the nominal cell constant. USP - HI98197 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met. 5-Point Calibration - Calibration can be performed up to five points with seven preprogrammed conductivity standards. For salinity ( % NaCl range) , HI7037 standard allows users to perform a one-point calibration. Temperature Compensation - EC and TDS measurements are fully customizable and include: cell constant selection between 0.0 and 10.000 and a selection of linear, non-linear ( natural water) or no temperature compensation. The temperature compensation coefficient range is configurable from 0.00 to 10.00% / ° C with a choice of reference temperatures of 15° C, 20° C and 25° C. TDS Conversion Factor - The conductivity to TDS factor is adjustable from 0.40 and 1.00. User Profiles - The HI98197 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors. Logging - The log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’ s HI920015 micro USB cable and HI92000 software. Good Laboratory Practice ( GLP) - GLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor ( TDS) is directly accessible by pressing the dedicated GLP key. Contextual Help - Access Help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed. Graphic LCD - The high contrast graphic LCD is easy to read outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages. Thermoformed Carrying Case - The compact, durable HI720197 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter and probe, beakers and conductivity standards. Specifications EC Range 0.000 to 9.999 ¼ S/ cm; 10.00 to 99.99 ¼ S/ cm; 100.0 to 999.9 ¼ S/ cm; 1.000 to 9.999 mS/ cm; 10.00 to 99.99 mS/ cm; 100.0 to 1000.0 mS/ cm ( actual conductivity; temperature compensated to 400 mS/ cm) EC Resolution 0.001 ¼ S/ cm; 0.01 ¼ S/ cm; 0.1 ¼ S/ cm; 0.001 mS/ cm; 0.01 mS/ cm; 0.1 mS/ cm EC Accuracy ± 1% of reading ( ± 0.01 ¼ S/ cm or 1 digit, whichever is greater) EC Calibration automatic up to five points with seven memorized standards ( 0.00 ¼ S/ cm, 84.0 ¼ S/ cm, 1.413 mS/ cm, 5.00 mS/ cm, 12.88 mS/ cm, 80.0 mS/ cm, 111.8 mS/ cm) TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt ( g/ L) ; 10.00 to 99.99 ppt ( g/ L) ; 100.0 to 400.0 ppt ( g/ L) TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt ( g/ L) ; 0.01 ppt ( g/ L) ; 0.1 ppt ( g/ L) TDS Accuracy ± 1% of reading ( ± 0.05 mg/ L ( ppm) or 1 digit, whichever is greater) TDS Calibration based on conductivity calibration Resistivity Range 1.0 to 99.9 © • cm; 100 to 999 © • cm; 1.00 to 9.99 K© • cm; 10.0 to 99.9 K© • cm; 100 to 999 K© • cm; 1.00 to 9.99 M© • cm; 10.0 to 100.0 M© • cm Resistivity Resolution 0.1 © • cm; 1 © • cm; 0.01 K© • cm; 0.1 K© • cm; 1 K© • cm; 0.01 M© • cm; 0.1 M© • cm Resistivity Accuracy ± 1% of reading ( ± 10 © or 1 digit, whichever is greater) Resistivity Calibration based on conductivity calibration Salinity Range % NaCl : 0.0 to 400.0% ; practical salinity: 0.00 to 42.00 ( PSU) ; natural seawater scale - UNESCO 1966: 0.00 to 80.00 ( ppt) Salinity Resolution 0.1% ; 0.01 Salinity Accuracy ± 1% of reading Salinity Calibration max. one point only in % range ( with HI7037 standard) ; use conductivity calibration for all other ranges Temperature Range -20.0 to 120.0° C ( -4.0 to 248.0° F) Temperature Resolution 0.1° C ( 0.1° F) Temperature Accuracy ± 0.2° C; ± 0.4° F ( excluding probe error) Temperature Calibration one or two points Temperature Compensation noTC, Linear ( -20 to 120 ° C; -4 to 248° F) , Non Linear - ISO/ DIN 7888 ( -0 to 36 ° C; 32 to 96.8° F) Measurement Modes autorange, autoend, lock and fixed range Reference Temperature 15° C, 20° C and 25° C Temperature Coefficient 0.00 to 10.00 % / ° C TDS Factor 0.40 to 1.00 Electrode/ Probe HI763123 platinum, four ring conductivity/ TDS probe with internal temperature sensor and 1 m cable ( included) Log-on-demand 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min ( max 1000 samples) Memorized Profiles up to 10 PC Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable Battery Type/ Life 1.5V AA batteries ( 4) / approximately 100 hours of continuous use ( without backlight) , 25 hours with backlight Auto-off user selectable: 5, 10, 30, 60 min or can be disabled Environment 0 to 50° C ( 32 to 122° F) ; RH 100% ( IP67) Dimensions 185 x 93 x 35.2 mm ( 7.3 x 3.6 x 1.4” ) Weight 400 g ( 14.2 oz.)
Tampilkan Lebih Banyak
Kontak Kami