Back to Top

1
Hi, Guest!
  • HACH - Formula for water analysis.
  • HQ40D Portable Multi Meter pH, Conductivity, Salinity, TDS, Dissolved Oxygen (DO), ORP and ISE For Water multiparameter water quality meter

HQ40D Portable Multi Meter PH, Conductivity, Salinity, TDS, Dissolved Oxygen (DO), ORP And ISE For Water Multiparameter Water Quality Meter

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail HQ40D Portable Multi Meter PH, Conductivity, Salinity, TDS, Dissolved Oxygen (DO), ORP And ISE For Water Multiparameter Water Quality Meter

HQ40D Portable Multi Meter pH, Conductivity, Salinity, TDS, Dissolved Oxygen (DO), ORP and ISE For Water

Product #:HQ40D53000000

Multiparameter: Plug-and-Play any Two Intellical Probes!

Designed for your water quality applications measuring pH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP and ISE, the Hach HQ40D portable multi meter is a two channels advanced handheld digital meter that takes the guesswork out of measurements. The Hach HQD digital multimeter combines reliability, flexibility and ease of use. The HQD portable meters connect with a wide range of Intellical smart electrodes addressing different parameters, sample types and operating environment for water quality, environmental and treatment process purposes. The Intellical probe automatically recognize the testing parameter, store the calibration history, and method settings to minimize errors and setup time. In their Rugged outdoor version the Intellical sensors are nearly indestructible and available with multiple cable lengths.

  • Rugged multi meter for outstanding and flexible field water testing.
  • Intuitive user interface for simple operation, reliable and accurate results
  • Trust your measurements - Intellical™ smart probes store all calibrations in the probe
  • Easy to Use in the Field
  • Designed for demanding field operating conditions

Rugged multi meter for outstanding and flexible field water testing.

Dual input channels for flexible measurements without the need for multiple instruments, for pH, Conductivity, Resistivity, Total Dissolved Solids (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Oxidation Reduction Potential (ORP), Ammonia, Ammonium, Fluoride, Chloride, Sodium, and temperature - connect to any Intellical™ smart electrode, sensor or probe.

Intuitive user interface for simple operation, reliable and accurate results

Guided calibration and check standard routines reduce calibration errors while stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results. Calibration status indicator and custom calibration alerts ensure accurate results.

Trust your measurements - Intellical™ smart probes store all calibrations in the probe

Calibration history allows quick and easy change out of probes without re-calibrating. The HQD™ smart system records serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log for complete Good Laboratory Practice (GLP) traceability. Error-free O2 results without calibration or replacing the electrolyte.

Easy to Use in the Field

All connections between the meter and the probe are secure and waterproof. Connectors can be color-coded for quick identification. Information is clearly displayed on the one screen with back light for low light conditions. Display results can be enlarged.

Designed for demanding field operating conditions

Rugged and waterproof meter design provides worry-free, reliable operation in field environments.

 What's in the box?

Meter package includes HQ40D Portable Meter; 4 AA batteries; Power adapter, USB/DC power adapter for data transfer; quick-start guide and user manual; Standard Field case; Protective Glove for Portable HQd Meter; 120 mL Sample Container (x5).

 Specifications

AC Power Adapter and USB/DC Adapter:Included
Automatic Buffer Recognition:Yes
Barometric Pressure Measurement:Automatic compensation of DO when using an LDO or LBOD probe
Calibration:Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder:Off, Selectable from 2 hours to 7 days
Compliance Certifications:CE.WEEE
Conductivity measurement:Yes
Conductivity measurement: Temperature correction:None; Linear; NaCl Non-Linear Natural Water.
Conductivity Measurement Range:0.01 µS/cm - 200.0 mS/cm
Conductivity resolution:0.01 µS/cm - 0.1 mS/cm upon selected measuring range
Contents:Meter Only
Custom Calibration Standards:Yes
Data Export:Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
Data Memory:500 records/FIFO
Data Storage:Automatic, GLP ISO compliant reading data stored with calibration details.
Digital (intelligent) electrode inputs:2 channels
Display:Detailed mode/Large mode
Display Lock Function:Continuous / Auto-stabilization ("press to read") / At Interval
Display Type:240 x 160 pixel LCD with backlight illumination
DO Measurement Range:0.1 - 20.0 mg/L (ppm) 1 - 200% saturation
DO Resolution:0.1
DO sensor calibration:* 100% (water-saturated air (100%) calibration
* 100% with 0 (water-saturated air (100%) calibration with 0 point
* mg/L (calibration with a specified dissolved oxygen concentration (mg/L) solution)
* mg/L with 0 (calibration with a specified dissolved oxygen concentration (mg/L) solution with 0 point)
* Factory (calibration with the default LDO calibration)
GLP Features:Date; Time; Sample ID; Operator ID
Inputs:2
Instrument:Portable
IP Rating:IP67
ISE Direct Measurement Range:Yes
ISE Electrode Calibration:2 - 5 Points
Languages:English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian
Measurement Method:Probe specific programmed method settings
Model:HQ40D – Multi/2 Channels
mV Measurement at Stable Reading:Yes
mV Measurement Range:-1500 - 1500 mV
mV Resolution:0.1 mV
Needed Cable Length:NA
Operating Error Messages:Clear text error messages displayed
Operating Humidity:90 % relative humidity (non-condensing)
Operating Interface:Soft Touch Keypad
Operating Temperature:0 - +60 °C (32 - 140 °F)
ORP Electrode Calibration:Predefined ORP standards (including Zobell's solution)
Parameter:pH/Oxydo Reduction Potential (ORP)
Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity
Dissolved Oxygen (DO)
Biochemical Oxygen Demand (BOD)
Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium
Parameters:NA
NA
NA
PC Data Transfer Software:HQd Series Meter Data Transfer Utility
pH Buffer Sets:Color-coded: 4.01, 7.00, 10.01 pH;
IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45
DIN: 1.09, 4.65, 9.23
User-defined custom buffer sets
pH Electrode calibration:1 - 3 Calibration points
Calibration summary data logged and displayed
pH Measurement Range:0 - 14 pH
pH Resolution:Selectable:
0.001/0.01/0.1 pH
Printer:Yes, Optional
Probes included:None
Probe Type:IntelliCAL Standard Laboratory or Rugged Field
Region:US
Salinity Measurement Range:0 - 42 (ppt) (‰)
Salinity Resolution:0.01 (ppt) (‰)
Sensors:Sensor A: None
Sensor B: None
Sensor C:
Simultaneous measurements:Yes, 2 channels
TDS Measurement Range:0.00 mg/L - 50.0 g/L NaCl
TDS Resolution:0.01 mg/L up - 0.1 g/L upon measuring range
Temperature Compensation:Automatic Temperature compensation for pH
 Automatic Temperature compensation for pH
Temperature Measurement:°C or °F
Temperature Resolution:0.1
Type of Measurement:Portable/Field Water Quality Applications
Warranty:3 years
Weight:335 g (0.75 lb) without batteries; 430 g (0.95 lb) with

Parameter/Range/Reagent Information

Ammonia Method Range Reagent Set(s) USEPA Compliant?
  10001 Direct Measurement ISE Method 0.05 - 14,000 mg/L as N View  
  10001 Direct Measurement ISE Method 0.1 - 10.0 mg/L NH3-N View Y
BOD (Biochemical Oxygen Demand) Method Range Reagent Set(s) USEPA Compliant?
  10360 0.05 - 20.00 mg/L BOD View  
Conductivity Method Range Reagent Set(s) USEPA Compliant?
  8160 Direct Measurement Method 0.01 - 200,000 µS/cm View Y
Dissolved Oxygen Method Range Reagent Set(s) USEPA Compliant?
  10360 Direct Measurement, LDO Probe (EPA) 0.1 - 20 mg/L View  
Fluoride Method Range Reagent Set(s) USEPA Compliant?
  8323 Direct Measurement ISE 0.02 - 19,000 mg/L F-    
  8323 ISE Electrode, Direct Measure in Acid Solutions 0.1 - 100.0 Mg/L F View  
  8323 ISE Electrode, Direct Measure, Drinking Water, PP or TISAB 0.1 - 10.0 mg/L F- View Y
Nitrate Method Range Reagent Set(s) USEPA Compliant?
  8359 Direct Measurement ISE 0.04 - 4.00 mg/L NO3 -N View  
Oxidation-Reduction Potential (ORP) Method Range Reagent Set(s) USEPA Compliant?
  10228 Direct Measurement -1999 - 1999 mV View  
pH Method Range Reagent Set(s) USEPA Compliant?
  8156 pH Meter Electrode Method 0 - 14 pH View Y