IFX-110A/120A/130A Atomic Absorption Spectrometer

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail IFX-110A/120A/130A Atomic Absorption Spectrometer

IFX-110A/120A/130A

Description

IFX-110A/120A/130A

Flame/Graphite Furnace Atomic Absorption Spectrophotometer

 

Features:

 

Innovated rich oxygen air-acetylene flame analysis technique (IFX-110A) :

The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adjustable between 2300-2950?, with makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It's break-through in flame AAS analysis

 

Integrated flame/graphite furnace atomization system, changeable with flame emission burner

- Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor

- A flame emission burner head can be installed to perform flame emission analysis to akali metais as K, Na etc.(IFX-110A/120A)

 

Accurate fully automated control system

- Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position

- Automatic wavelength scanning and peak picking

- Automatic spectral bandwidth changing<

- Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters and automatic ignition

 

Reliable fully automatic graphite furnace analysis

- Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%

- Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact

 

Perfect safety protection measures

- Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

- Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling wate supply and over-heating in graphite furnace system

 

Advance and reliable electronic design

- Adopting large-scale programmable logic array and Inter I2C bus technology

- European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

 

7 Easy and practical analysis software

- Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization

- Automatic sample dilution, automatic curve fitting, automatic sensitivity correction

 

Specifications :

Main Specification

Wavelength range

190-900nm

Wavelength accuracy

Better than ±0.25nm

Resolution

Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.

Baseline stability

0.004A/30min

Background correction

The D2 lamp background correction capability at 1A is better than 30 times

Hollow Cathode Lamps

Lamp turret

The S-H background correction capability at 1.8A is better than 30 times.( only for IFX-110A/120A)

Lamp current adjustment

400Hz square wave pulse

Wide pulse current: 0~25mA,
Narrow pulse current: 0~10mA

Lamp power supply mode

400Hz square wave pulse;

100Hz narrow square wave pulse+400Hz wide square wave pulse (IFX-110A/120A)

Optical System

Monochomator

Single beam, Czerny-Turner design grating monochromator

Grating

1800 l/mm

Focal length

277mm

Blazed Wavelength

250nm

Spectral Bandwidth

0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change

Flame Atomizer

Burner

10cm single slot all-titanium burner

Spray chamber

Corrosion resistant all-plastic spray chamber

Nebulizer

High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min

Emission burner

Provided with IFX-110A/120A

Graphite Furnace

Temperature range

Room temperature~3000ºC

Heating rate

2000?/s

Graphite tube dimensions

28mm(L)×8mm(OD)

Characteristic mass

Cd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g

Precision

Cd≤3%, Cu≤3%, Mo≤4%

Detection and Data Processing System

Detector

R928 Photomultiplier with high sensitivity and wide spectral range.

Software

Windows operating system

Analytical method

Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.

Repeat times

Maximum 20 times of repeat measurement, automatic calculation of mean value, standdard deviation and relative standard deviation.

Multi-task Functions

Sequential measurement for multi-element determination in one sample

Condition reading

With model function

Result printing

Measurement data and final analytical report printout, editing with Excel

Standard RS-232 serial port communication

Characteristic Concentration and Detection Limit

Normal Air-C2H2 flame

 

Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;

Rich Oxygen Air-C2H2 flame

Ba: Characteristic concentration ≤ 0.22mg/L

Al : Characteristic concentration ≤ 0.4mg/L

Function Expansion

Hydride vapor generator can be connected for hydride analysis

Dimensions and weight

Main unit

102×49×54cm, unpacked 80kg

Graphite furnace

42×42×46cm, unpacked 50kg

Tampilkan Lebih Banyak