Back to Top

1
Hi, Guest!

KYORITSU Non-Contact Safety Phase Indicator KEW 8035

Update Terakhir
:
05 / 03 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail KYORITSU Non-Contact Safety Phase Indicator KEW 8035

Alat Laboratorium Mikrobiologi

Deskripsi produk
• New technology permits safe testing, without the need of direct contact between probes and live wires.
• The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm.
• Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.
• The instrument can be fixed to a metal panel via the magnet on the back side.
• Wide measuring range for 3 phase installations from 70V to 1000V AC.
• Super brightness function permits clear LED's indication also in sunshine.
• Complies with IEC 61010-1 CAT IV 600V and CAT III 1000V.




Functions
Phase rotation (Clockwise or Counter Clockwise),
Presence of open phase
Detection method
Electrostatic induction
Measuring voltage range
From 70 to 1000V AC phase to phase (sine wave, continuous input)
Clamp diameter range
From Ø2.4 to 30mm insulated cables
Measuring frequency range
45 to 66Hz
Phase rotation
Clockwise:
Green arrow LEDs "rotate" in clockwise, Green symbol "CW" lits, Intermittent buzzer

Counter Clockwise:
Red arrow LEDs "rotate" in counter clockwise, Red symbol "CCW" lits, continuous buzzer
Visual indication
Via LEDs with Super brightness function
Battery voltage warning
Power LED blinks if battery voltage is too low.
Test leads
Double insulated cables, length approx. 70cm
Colours code
L1(U): RedL2(V): WhiteL3(W): Blue
Applicable standards
IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree2,
IEC 61326-1, IEC 61557-1, -7
Operating temperature & humidity range
Temperature/Humidity Ranges -10 to 50ºC, 80% (no condensation)
Storage temperature & humidity range
Temperature/Humidity Ranges -20 to 60ºC, 80% (no condensation)
Power supply (DC battery)
LR6(AA)(1.5V) ×4
* Continuous use: Approx. 100 hours (Auto power off in about 10 min.)
Dimensions
112(L) × 61(W) × 36(D) mm
Weight
380g approx.
Included Accessories
9096 (Carrying case), LR6(AA) × 4, Instruction manual