Detail KYORITSU Power Meter KEW 6305
Alat Laboratorium Mikrobiologi
Deskripsi produk
• Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
• Voltage, Current, Power Factor and Frequency measurements
• Power analysis (Active, Apparent and Reactive power)
• Energy analysis (Active, Apparent and Reactive power)
• Active power accuracy: ±0.3%rdg±0.2%f.s.
• Automatic wiring check function to prevent incorrect connections
• Large memory capability (2GB) using built-in SD card interface
• Real time & remote measurements using Android application
• synchronous measurements between two units of KEW 6305
• Wide selection of clamp sensors allow measurements from 0.1A to 3000A
• The instrument automatically recognizes what kind of clamp sensor is connected to it
• Windows software for data analysis and setting via USB port or Bluetooth
Wiring connections
1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
Measurements
Voltage, Current, Frequency, Active power
Parameters
Apparent power, Reactive power, Active energy, Apparent energy,
Reactive energy, Power factor (cos θ), Neutral current
Voltage range[RMS]
150.0 / 300.0 / 600.0V
Voltage accuracy
±0.2%rdg±0.2%f.s. (sine wave, 45 - 65Hz)
Current range[RMS]
8128/8135 ( 50A type ) : 1.000 / 5.000 / 10.00 / 25.00 / 50.00A / auto
8127 ( 100A type ) : 2.000 / 10.00 / 20.00 / 50.00 / 100.0A / auto
8126 ( 200A type ) : 4.000 / 20.00 / 40.00 / 100.0 / 200.0A / auto
8125 ( 500A type ) : 10.00 / 50.00 / 100.0 / 250.0 / 500.0A / auto
8124/8130( 1000A type ) : 50.00 / 100.0 / 200.0 / 500.0 / 1000A / auto
8133 ( 3000A type ) : 60.00 / 300.0 / 600.0 / 1500 / 3000A / auto
Current accuracy
±0.2%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45 - 65Hz)
(*) +1%f.s. at the lowest range
Display range
5 - 130% of each range(Voltage)
1 - 130% of each range(Current)
Crest factor
Voltage: up to 2.5, Current: up to 3.0 (with 90% fs or less)
Effect of power factor
Active power: ±1.0%rdg cos θ=±0.5 (PF=1)
Frequency meter range
40.0 - 70.0Hz
Frequency meter accuracy
±3dgt
Accuracy precondition
PF=1, Sine wave, 45 - 65Hz, 23ºC±5ºC
Display update period
1 second
Applicable standards
IEC 61010-1 CAT III 600V
Operating temperature & humidity range
0 - +50ºC, less than 85%RH (without condensation)
Storage temperature & humidity range
-20 - +60ºC, less than 85%RH (without condensation)
Power supply (AC Line)
AC100 - 240V±10% (50/60Hz)
Power supply (DC battery)
LR6 or Ni-MH (HR-15-51) ×6 (Battery charger not included),
Battery life approx. 15h (LR6)
Power consumption
10VA (max.)
Communication interface
USB, Bluetooth
PC card interface
SD card (2GB)
Dimensions
175(L)×120(W)×65(D) mm
Weight
Approx. 800g (including batteries)
Included Accessories
7141B (Voltage test lead set: 4pcs)
7148 (USB cable)
7170 (Power cord)
8326-02 (SD card 2GB)
9125 (Carrying case for KEW 6305, KEW 6305-01)
9135 (Carrying case for KEW 6305-03, KEW 6305-05)
KEW Windows for KEW 6305 (PC Software)
Battery (LR6)×6
Quick manual
Optional Accessories
8124/8125/8126/8127/8128 (Load current Clamp Sensor)
8130/8133(*1)/8135(*2) (Flexible clamp sensor)
8312 (Power supply adaptor)
9132 (Magnetic carrying case)
*1 Can be used with firmware version V1.10 or later for KEW 6305.
*2 The firmware version of KEW 6305 is V2.00 or later, and the serial number is "No.8369312" or later.
Please check here for the latest firmware.
Power Meter and clamp sensor set model
*Included accessories for below models are same with above-mentioned.
KEW 6305-018125 (500A: φ40mm) × 3
Carrying case: 9125
KEW 6305-038130 (1000A : φ110mm) × 3
Carrying case: 9135
KEW 6305-058133 (3000A : φ170mm) × 3
Carrying case: 9135
Hubungi :
Juni Tarigan (Mr.)
0811 198 0702
Pera (Ms.)
0811 3801 0819
Admin
0813-2310-201
PT. ANDALAN BANGUN SEJAHTERA
Jl. Sumur Batu No. 1, Kemayoran
Jakarta Pusat - Indonesia 10640
Telp : +6221-42803207, 4227517
Fax : +6221-42803208