Detail KYORITSU Voltage Testers KT 171

Alat Laboratorium Mikrobiologi

Deskripsi produk
• AC and DC voltage tests up to 690V with LEDs and LCD
• Comply with the latest standards IEC 61243 and IEC 61010
• Novel design
Large and bright LEDs: Values are visible in the dark place
Ergonomic design fits in the hand
• Two functions are available in one model
"Measurement without battery" and "Self Test (all LED on)"
• Test leads withstand harsh environments at low temperature
• Penlight (white LED)
• Auto-power ON/OFF
• Audible indication
• Variable test tips, φ2mm or φ4mm
• Probe protection cover can store the attachment of caps
• IP65 (IEC 60529)



Voltage Test (Double-pole Test)
Single-pole Phase Test


Variable top tips
Store the attachment of caps


Probe Protection Cover
4mm Tips Replacement

How to fixing 4mm Tips on
L1 probe- and L2 probe+.


Voltage Test
Voltage Range
12 - 690V AC/DC
LED
Nominal Voltage
12/24/50/120/230/400/690V
AC (16 - 400Hz), DC (±)
Tolerance
(Threshold Voltage)
Light on at more than:
7±3V (12V LED)
18±3V (24V LED)
37.5±4V (50V LED)
75%±5% of nominal voltage
(120/230/400/690V LED)
Response Time
<0.6s at 100% of each nominal voltage
LCD
Range/Resolution
(Auto-range)
300V AC/DC (6.0 - 299.9)/0.1V
690V AC (270 - 759)/1V
690V DC (270 - 710)/1V
Accuracy (23±5ºC)
±1.5V (7 - 100V)
±1%±5dgt (100 - 690V)
AC (16 - 400Hz), DC(±)
Overrange Indication
"OL"
Response Time
Approx. 1s at 90% - 100% of each voltage
Peak Current
ls<3.5mA (at 690V)
Measurement Duty
30s ON (operation time)
240s OFF (recovery time)
Single-Pole Phase Test
Voltage Range
100 - 690V AC (50/60Hz)
Phase Rotation Test
System
Three-phase 4-wire system
200 - 690V phase-to-phase AC (50/60Hz)
Phase Range
120±5 degree
Continuity Test
Detection Range
0 - 400kΩ+50%
Test Current
Approx. 1.5μA (battery 3V, 0Ω)
Applicable standards
IEC 61243-3, IEC 61010-1, IEC 61557-7
CAT Ⅲ 690V / CAT Ⅳ 600V Pollution degree 2
IP Rating
IP65 (IEC 60529)
Operating temperature & humidity range
-15 - 55ºC, max 85% RH (No Condensation)
Storage temperature & humidity range
-20 - 60ºC, max 85% RH (No Condensation)
Power source
LR03 (AAA) 1.5V×2
Dimensions
246(L)×64(W)×26(D) mm
Weight
190g (including batteries)
Included Accessories
LR03 (AAA) 1.5V×2, KTA01 (4mm metal tips [2pcs/set]),
KTA02 (4mm rubber caps [2pcs/set]), Instruction manual