Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, acceleration and rotation due to complete isolation between channels and from each channel to the ground.


 
• Max. 16ch Analog + 16ch Logic • Max. 10ch Analog + 64ch Logic • 20M-Sampling/s • 32M to 256M-Word Memory (2ch) • Waveform judgment function • 12-bit/16-bit A/D resolution • USB, HD, CF-card




Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Number of channels [8 analog input modules]: 16 analog channels + 16 logic channels (standard)
[5 analog input modules + 3 logic input modules]: 10 analog channels + 64 logic channels (standard 16 channels + 48 channels in logic input modules)
* For analog modules, channels are insulated vs. each other and vs. unit ground. For logic modules and integrated standard logic channels, all channels use the unit ground. Measurement ranges (20 div full-scale) 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (using the 8966)
5 mV to 50 V/div, 5 ranges, resolution : 1/1 000 000 of range (using the MR8990)
200 mV to 50 V/div, 8 ranges, resolution : 1/1600 of range (using the U8794) Max. allowable input 400 V DC (using the 8966/8968), 500 V DC (using the MR8990), 1000 V DC (using the U8974) Frequency characteristics (-3dB) DC to 5 MHz (using the 8966), DC (using the MR8990), DC to 100 kHz (using the U8794) Time axis (Memory function) 5 µs to 5 min/div (100 samples/div) 26 ranges, External sampling (100 samples/div, or free setting), Time axis zoom: x2 to x10 in 3 stages, compression: 1/2 to 1/200 000 in 16 stages Measurement functions MEMORY (high-speed recording), RECORDER (real-time recording), X-Y RECORDER (X-Y real-time recording), FFT Other functions Waveform judgment (at Memory or FFT function) Memory capacity MR8847-51: Total 64 M-words (Memory expansion: none)
32 MW/ch (using 2 Analog channels), to 4 MW/ch (using 16 Analog channels)
MR8847-52: Total 256 M-words (Memory expansion: none)
128 MW/ch (using 2 Analog channels), to 16 MW/ch (using 16 Analog channels)
MR8847-53: Total 512 M-words (Memory expansion: none)
256 MW/ch (using 2 Analog channels), to 32 MW/ch (using 16 Analog channels) Removable storage CF card slot (standard) ×1 (up to 2GB, FAT, or FAT-32 format), SSD (128 GB, optional), USB memory stick (USB 2.0) Printing 216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s Display 10.4 inch TFT color LCD (SVGA, 800 × 600 dots) Displayable languages English, Japanese, Korean, Chinese External interfaces [LAN] 100BASE-TX (FTP server, HTTP server), [USB] USB2.0 compliant, series A receptacle ×1, series B receptacle ×1, (File transfer internal drive/CF card to PC, or remote control from PC) Power supply 100 to 240 V AC, 50/60 Hz (130 VA max., when using printer: 220 VA max.)
10 to 28 V DC (when using the optional factory-installed DC power unit 9784) Dimensions and mass 351 mm (13.82 in) W × 261 mm (10.28 in) H × 140 mm (5.51 in) D, 
7.6 kg (268.1 oz) (main unit only) Accessories Instruction manual ×1, Measurement guide ×1, Application disk (Wave viewer Wv, Communication commands table) ×1, Power cord ×1, Input cord label ×1, USB cable ×1, Printer paper ×1, Roll paper attachment ×2, Ferrite clamp ×1

LabVIEW and MATLAB support





Compatible models LabVIEW MATLAB script MR8847-51 Available Available MR8847-52 Available Available MR8847-53 Available Available