Back to Top

1
Hi, Guest!
  • PCE PCE
  • PCE Formaldehyde Meter AQ-300 Set EF

PCE Formaldehyde Meter AQ-300 Set EF

Update Terakhir
:
30 / 08 / 2024
Min. Pembelian
:
1 Unit

Harga

Rp. 100
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail PCE Formaldehyde Meter AQ-300 Set EF


PCE Formaldehyde Meter AQ-300 Set EF
Instrument Laboratorium

Deskripsi produk
DESCRIPTION
Formaldehyde Tester AQ-300 Set EF /
Broad range of application / Alarm function


The Gas Detector AQ-300 is a highly accurate instrument for measuring ozone concentrations in the air. The Gas Detector can be equipped with four different heads that vary in their measurement range. Furthermore, the Gas Detector has sensor heads for other gases available, which are automatically recognized when plugged into the device. Thus, you can use the Gas Detector in many different areas. The possibilities of the Gas Detector extend the use of ozone in your processes for bleaching oils, greases, wax, paper, synthetic fibers, cellulose or textiles,within the paper, textile, or lubricant production industries. Another field of application for the Gas Detector is in cleaning, disinfection and sterilisation of swimming pools, water treatment facilities or after fire damage or water damage. With a head for lower measurements of up to 0.150 ppm, you can measure ozone concentrations that have a negative effect on the mental state of humans.



Thanks to the leading GSS technology of the sensors, the Gas Detector not only is high precision, it also has a long lifespan. The unique possibility to refresh the sensors makes their maintenance more economical than the maintenance of other types of sensors. Depending on the model, the measured concentrations may be written to the internal memory of the Gas Detector via an analog interface with a 0... 5 V output, or the output is transferred via a USB interface to a PC. Similarly, a remote kit is available as an option, allowing the Gas Detector to take measurements in a secure room while the sensor is connected via cable to the Gas Detector. Through simplicity of operation the alarm thresholds for the optical or acoustic signal can be changed in a very short time. In addition to the measured concentrations in the LCD display, which are displayed in ppm or mg / m³, the high and low alarms are shown.




HIGHLIGHTS
- High accuracy and functionality
- Easy to operate and maintain
- Fast response time
- Interchangeable sensor heads
- LCD display
- Battery operation
- Alarm function
- Sensor calibration function
- Max. / Min. / Average function
- Analog output
SPECIFICATION
As Model 200 Series, in addition:
Alarm function
"High", "Low", Mute
Alarm output
Transistor output, 150-mA max
Low Alarm, High Alarm & Control
Analog output
0... 5V
Location ID
Storage of the measuring location
Model 200, 300 and 500 Series
Power supply
12V DC
Rechargeable battery
Lithium-Polymer 12V DC / 2700 mAh
Charger
12.6V 2 A
Charging voltage
12.6V
Charging time
2... 3 hours
Lifecycle
> 500 charges
Housing
PC & ABS / IP20 & NEMA 1
Dimensions (incl. opt. sensorsavailable)
7.7 x 4.8 x 2.1 in / 195 x 122 x 54 mm
Weight
< 1 lb / 460 g (with battery)
Approvals
EN 50082-1: 1997, EN 50081-1: 1992, CE

Optional accessories for the gas detector:

Sensors:
Gas
Code
Meas. (ppm)
Min.
(ppm)
Meas.
(ppm)
Resolution.
(ppm)
Temp. °C/ humidity. %
GSS sensors (semiconductor sensors):
Ozone
(O3) OZU
0 ... 0.15
0.001
< ±0.005 %
0.001
0 ... +40
10 ... 90
Ozone
(O3) OZL
0 ... 0.5
0.001
< ±0.008

0 ... 0.1
0.001
0 ... +40
10 ... 90
Ozone
(O3) OZG
0 ... 10
0.01
< ±0.1
0...1
0.01
0 ... +40
10 ... 90
Hydrogen
(H2) HA
0 ... 5000
5
< ±10 %
1
0 ... +40
10 ... 90
Chlorine
(CL2) ECL
0 ... 10
0.1
< ±10 %
0.01
0 ... +40
10 ... 90
Ozone (O3)

Leakage finder OZK

0.01

0.01
0 ... +40
10 ... 90
Methane
(CH4) MT
0 ... 10,000
10
< ±15 %
1
0 ... +40
10 ... 90
NMHC
VN
0 ... 25
0.1
< ±10 %
0.1 ... 25
0.1
0 ... +40
10 ... 90
Tetrachlorethylene
(C2CL4) PE
0 ... 200
1
< ±5
0 ... 50
1
0 ... +40
10 ... 90
(VOC)
VM
0 ... 25
0.1
±10 %
0.1
0 ... +40
10 ... 90
(VOC)
VP
0 ... 500
1
±10 %
1
0 ... +40
10 ... 90

GSE sensors (electrochemical sensors):
Ammonia
(NH3) ENG
0 ... 100
0.2
±10 %
0.1
0 ... +40
10 ... 90
Carbon monoxide (CO) ECN
0 ... 100
0.1
< ±1
0... 10
0.1
0 ... +40
10 ... 90
Carbon monoxide
(CO) ECM
0 ... 25
0.02
< ±0.5
0 ... 5
0.01
0 ... +40
10 ... 90
Formaldehyde
(CH2O) EF
0 ... 10
0.01
< ±0.05
0 ... 0.5
0.01
0 ... +40
10 ... 90
Sulfur-
hydrogen (H2S) EHS
0 ... 10
0.01
< ±0.05
0 ...0.5
0.01
0 ... +40
10 ... 90
Sulfur-
hydrogen (H2S) EHT
0 ... 100
0.2
< ±0.5
0 ... 5
0.1
0 ... +40
10 ... 90
Nitrogen dioxide (NO2) ENW
0 ... 1
0.002
< ±0.02
0 ... 0.1
0.001
0 ... +40
10 ... 90
Sulfur dioxide (SO2) ESO
0 ... 10
0.01
< ±0.05
0 ... 0.5
0.01
0 ... +40
10 ... 90
Sulfur dioxide (SO2) ESP
0 ... 100
0.2
< ±0.05
0 ... 0.5
0.1
0 ... +40
10 ... 90
Tampilkan Lebih Banyak
Kontak Kami