Back to Top

1
Hi, Guest!
  • PERKIN ELMER
  • PERKIN ELMER NexION 5000 Multi-Quadrupole ICP Mass Spectrometer

PERKIN ELMER NexION 5000 Multi-Quadrupole ICP Mass Spectrometer

Update Terakhir
:
17 / 04 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail PERKIN ELMER NexION 5000 Multi-Quadrupole ICP Mass Spectrometer

Alat Laboratorium Mikrobiologi

Deskripsi produk
NexION 5000 Multi-Quadrupole ICP Mass Spectrometer

The NexION® 5000 multi-quadrupole ICP-MS – the first in its category to boast four quads – is innovatively designed to meet and exceed the demanding requirements of ultra-trace elemental applications. It takes ICP-MS performance beyond traditional triple quad to deliver exceptionally low background equivalent concentrations (<1 ppt, even in hot plasma) and outstanding detection limits, key to ensuring accurate, repeatable results. Plus, the NexION 5000 provides superior interference removal, phenomenal stability and unmatched matrix tolerance.

In addition to boasting four quads, the NexION 5000 is also the proud recipient of three awards: Wiley Analytical Science Award, The Analytical Scientist Innovation Award, and R&D 100 Award.

Part Number N8160010
Overview
The multi-award-winning NexION 5000 ICP-MS is equipped with a host of new and proprietary technologies which together surpass traditional triple-quad capabilities and redefine your expectations:

Four quadrupoles:First: Quadrupole Ion Deflector (Q0) directs ions to the entrance of the first mass filter
Second: Transmission Analyzer Quadrupole 1 (Q1, full-sized for <0.7 amu mass resolution), acts as a mass filter or as an ion guide to direct ions to the Quadrupole Universal Cell
Third: Quadrupole Universal Cell (Q2), empowered by dynamic bandpass tuning, prevents side reactions with residual gases in the cell
Fourth: Transmission Analyzer Quadrupole 2 (Q3, full-sized for <0.7 amu mass resolution), acts as a mass filter or as an ion guide to direct ions to the detector
Extended Dynamic Range (EDR) increases linear dynamic range to 1012, allowing to run both high and low concentration analytes in a single analytical run, resulting in fewer re-runs
Low maintenance for greater uptime:Triple Cone Interface with patent-pending OmniRing™ combined with Quadrupole Ion Deflector deliver no maintenance beyond cones​, for continual operation and improved stability
34 MHz free-running RF generator offers trouble-free user experience – the plasma is generated by the unique LumiCoil™ RF load coil, which is air cooled (does not require water or gas cooling), so maintenance-free, eliminating need to replace plasma load coils
External status lighting provides easy visibility of state of analysis, optimizing efficiencies
Syngistix™ for ICP-MS software (v. 3.0 or higher) brings together the power of the triple-quad ion optics with an user-friendly workflow in a contemporary user interface
Certified to be able to be upgraded to meet SEMI S2/S8 (emergency button) delivers ease of integration in clean room facilities

Specifications
Depth
85.0 cm
Height
85.0 cm
Product Brand Name
NexION
Weight
191.0 kg
Width
114.0 cm
Application Brief
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep into the lungs, where contaminants can have direct interaction with lung tissue and the associated blood vessels. Airborne particulates are classified as PM10 for those with aerodynamic diameters less than 10 µm and PM2.5 for those with aerodynamic diameters less than 2.5 µm.

PM2.5 regulations have been implemented throughout the world, and in order to implement a regime to reduce the concentration of PM2.5, it is important to determine the origins of these particulates, hence the need to collect and analyze them.

ICP-MS is often the analytical instrument of choice for such applications due to its low detection limits and wide linear dynamic range. This work describes the collection, sample preparation and inorganic elemental analysis of atmospheric PM10 and PM2.5 using PerkinElmer’s NexION® ICP-MS.

Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-4280320
Tampilkan Lebih Banyak
Kontak Kami