Detail Spectrophotometer Benchtop Grating YS6010 3NH

Spectrophotometer Benchtop grating YS6010 3NH

Alat laboratorium air

Technical Specification

Model YS6010 Benchtop Spectrophotometer
Optical Geometry
Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Application
It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere Size
Φ154mm
Light Source
360 nm to 780 nm, Combined LED Light, 400nm cut-off light source
Spectrophotometric Mode
Concave Grating
Sensor
256 Image Element Double Array CMOS Image Sensor
Wavelength Range
360-780nm
Wavelength Interval
10nm
Semiband Width
10nm
Measured Reflectance Range
0-200%
Measuring Aperture
Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ25.4mm;
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Component
Reflectance: SCI&SCE / Transmittance: SCI&SCE
Color Space
CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula
ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric Index
WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, APHA/Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle
2°/10°
Illuminant
D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30
Displayed Data
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time
About 2.4s (Measure SCI & SCE about 5s)
Repeatability
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error
Φ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
Dimension
L*W*H=370x300x200mm
Weight
Approx. 9.6kg
Power
AC 24V, 3A Power adapter power supply
Illuminant Life Span
5 years, more than 3 million times measurements
Display
7-inch TFT color LCD, Capacitive Touch Screen
Data Port
USB & Print serial port
Data Storage
Standard 2000 Pcs, Sample 20000 Pcs
Language
Simplified Chinese, Traditional Chinese, English,
Operating Environment
0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment
-20~50℃, 0~85%RH (no condensing)
Standard Accessory
Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber
Optional Accessory
Micro-printer, Transmissive Test Component, Instrument inversion components,culture dish
Notes
The specifications are subject to change without notice.