Detail Three-Phase Power Analyzer PCE-PA 8300-2


Three-Phase Power Analyzer PCE-PA 8300-2
Instrument Laboratorium

Deskripsi produk
DESCRIPTION
PCE-PA 8300 3-Phase Power Meter / 3-Phase Power Analyzer
3-phase / 3 current clamps / LCD graphic display / SD card memory

The PCE-PA 8300 is a 3-Phase Power Meter / 3-Phase Power Analyzer that features a durable enclosure, SD card memory, a LCD graphic display, as well as apparent, effective, and reactive power measurement. The easy-to-use PCE-PA 8300 3-Phase Power Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity.

Set 2: Includes 3 flexible Rogowski coils for measurements up to 3000 A AC
HIGHLIGHTS
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of 30 A ... 3000 A AC (Set 2)
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
- SD card memory
- LCD graphic display
- Durable enclosure
- Compatibility with various manufacturers' power clamps
- Adjustable back-up interval, allowing for long-term data collection
- Auto-setting of measurement range (AC V)
- Power efficiency, delay angle, and frequency measurement
- Apparent, effective, and reactive power measurement
- Harmonic spectrum measurement up to the 50th order
SPECIFICATION
Electrical specifications
Voltage Measurement (AC V)
Measurement Range
Resolution
Accuracy
10 V ... 600 V (phase to neutral)
0.1 V
±(0.5 % + 0.5 V)
10 V ... 600 V (phase to phase
0.1 V
±(0.5 % + 0.5 V)

Current measurement (AC A) Set 2
Measurement range
Resolution
Accuracy
30 A
0.001 A (< 10 A)
0.01 A (≥ 10 A)
±(0.5 % + 0.1 A)
300 A
0.01 A (< 10 A)
0.1 A (≥ 10 A)
±(0.5 % + 0.5 A)
3000 A
0.1 A (< 1000 A)
1 A (≥ 1000 A)
±(0.5 A + 5 A)
Effective power
Measurement range
Resolution
Accuracy
0 KW ... 9.999 KW
0.001 KW
±(1 % + 0.008 KW)
10 KW ... 99.99 KW
0.01 KW
±(1 % + 0.08 KW)
100 KW ... 999.9 KW
0.1 KW
±(1 % + 0.8 KW)
1 MW ... 9.999 MW
0.001 MW
±(1 % + 0.008 MW)
Apparent Power
Measurement range
Resolution
Accuracy
0 KVA ... 9.999 KVA
0.001 KVA
±(1 % + 0.008 KVA)
10 KVA ... 99.99 KVA
0.01 KVA
±(1 % + 0.08 KVA)
100 KVA ... 999.9 KVA
0.1 KVA
±(1 % + 0.8 KVA)
1 MVA ... 9.999 MVA
0.001 MVA
±(1 % + 0.008 MVA)
Reactive Power
Measurement range
Resolution
Accuracy
0 KVAR ... 9.999 KVAR
0.001 KVAR
±(1 % + 0.008 KVAR)
10 KVAR ... 99.99 KVAR
0.01 KVAR
±(1 % + 0.08 KVAR)
100 KVAR ... 999.9 KVAR
0.1 KVAR
±(1 % + 0.8 KVAR)
1 MVAR ... 9.999 MVAR
0.001 MVAR
±(1 % + 0.008 MVAR)
Active Energy
Measurement range
Resolution
Accuracy
0 KWH ... 9.999 KWH
0.001 KWh
±(2 % + 0.008 KWh)
10.00 KWH ... 99.99 KWH
0.01 KWh
±(2 % + 0.08 KWh)
100.0 KWH ... 999.9 KWH
0.01 KWh
±(2 % + 0.8 KWh)
1 MWH ... 9.999 MWH
0.001 MMh
±(2 % + 0.008 MWh)
Apparent Energy
Measurement range
Resolution
Accuracy
0 KVARH ... 9.999 KVARH
0.001 KVARh
± (2 % + 0.008 KVARh)
10.00 KVARH ... 99.99 KVARH
0.01 KVARh
± (2 % + 0.08 KVARh)
100.0 KVARH ... 999.9 KVARH
0.01 KVARh
± (2 % + 0.8 KVARh)
1 MVARH ... 9.999 MVARH
0.001 MVARh
± (2 % + 0.008 MVARh)
Power Factor
Measurement range
Resolution
Accuracy
0 ... 1
0.01
± 0.04
Delay Angle
Measurement range
Resolution
Accuracy
-180° ... +180°
0.1°
±1°
Frequency
Measurement range
Resolution
Accuracy
45 Hz ... 65 Hz
0.1 Hz
± 0.1 Hz
Harmonic of AC Voltage at 50 / 60 Hz
Measurement range
Resolution
Accuracy
1 ... 20th order
0.001 ... 1 A
0.1 %
± (2 % + 0.5 A)
± (2 % + 10 Digit)
21 ... 30th order
0.001 ... 1 A
0.1 %
± (2 % + 0.5 A)
± (2 % + 10 Digit)
21 ... 50th order
0.001 ... 1 A
0.1 %
not specified
General specifications
Display
3.7 in / 94.0 mm point-matrix LCD (320 * 240 pixel) with LED background lights
Safety standards
IEC1010CAT III 600V
Input resistance AC V
10 MOhm
Operating frequency of current clamp
40 Hz ... 1 kHz
Tested operating frequency of current clamp
45 Hz ... 65 Hz
Overload protection
AC V
AC A
720 V RMS
1300 A with current clamp
Data Storage
SD memory card
Refresh interval
1 second
Data logging function
logging with real-time speed on SD memory card
Record interval
2 ... 7200 seconds
Data output (only for live display on computer)
per USB or RS232, depending on connection cable
Operating temperature
0° C ... +50° C / 32° F ... 122° F
Surrounding humidity
< 80 % RH
8 x 1.5 V AA batteries
Voltage Supply
9 V adapter
Current Drain
Measurement Device: 300 mA DC
current clamp: 34 mA DC
Maximum Wire Diameter
50 mm / 1.9 in
Weight
Measurement Device: 948 g / 33.4 oz (incl. battery)
Current clamp: 467 g / 16.4 oz (incl. cable)
Dimensions
Device: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in
Current clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in
Clamp jaw: 86 mm / 3.3 in (exterior)
DELIVERY SCOPE
1 x PCE-PA 8300 3-Phase Power Meter / 3-Phase Power Analyzer
3 x Flexible Rogowski coils (Set 2)
4 x Insulated alligator clips
4 x Safety test lines
6 x 1.5 V AA batteries
1 x 9 V mains adapter
1 x SD memory card
1 x Carrying case
1 x User manual